3-223
Preload disk package with an axial force
of F = 50
+30
kN.
Then check the setting dimension "A" =
1.05
±
0.1 mm from the collar of the
differential cover to the plane face of the
outer disk (see also below sketch).
Pressure piece
5870 100 069
Load cell
5870 700 004
Any deviation from the specified setting
dimension must be corrected with a
corresponding outer disk.
A = Setting dimension = 1.05
±
0.1 mm
B = Contact face
To obtain a correct measuring result :
T h e h o u s i n g c ove r m ay o n l y b e
supported on the contact face (B).
Ensure that the assembly fixture is only
supported on the disk package and not
on the disk carrier (5).
⑬
※
⑭
7609AAX079
7609AAX080
Position housing cover onto pressure
piece (see arrow).
Insert two hexagon screws into the
housing cover to radially fix the disk
package.
Pressure piece
5870 100 075
⑮
Position the premounted differential with
the lifting device onto the housing cover
and preliminarily fix with hexagon
screws.
Lifting device
AA00 331 446
16
7609AAX081
7609AAX082