Leakage test of lock
Leakage test of lock
Pressurize the lock (p = 1 bar), close
shut-off valve and remove air line.
No noticeable pressure loss is allowed
No noticeable pressure loss is allowed
to occur within 10 sec.
to occur within 10 sec.
This operation is only necessary for
hydraulic lock diferential (option).
After the contact pattern check insert the
differential again into the axle drive
housing.
Load carrying device
5870 281 083
22
By rotating the input flange, roll crown
wheel over the input pinion in both
directions several times.
Then remove the axle housing again and
lift the differential out of the axle drive
housing.
Compare the obtained contact pattern.
I n c a s e o f a n y c o n t a c t p a t t e r n
I n c a s e o f a n y c o n t a c t p a t t e r n
deviation, a measuring error was
deviation, a measuring error was
made when deter mining the shim
made when deter mining the shim
(AX115, page 3-233), which must be
(AX115, page 3-233), which must be
corrected by all means.
corrected by all means.
※
21
20
7609AAX131
7609AAX132
7609AAX133