7-17
6. ELECTRIC
6. ELECTRIC PARKING, PILOT CUT OFF CIR
PARKING, PILOT CUT OFF CIRCUIT
CUIT
OPERATING FLOW
OPERATING FLOW
Parking OFF
Parking OFF
Fuse box [CN-39 (41)] Parking switch OFF [CS-17 (5)
→
(4)] I/conn [CN-05 (14)]
I/conn [CN-12 (13)]
Parking solenoid ON (activated)
Parking brake released (by hydraulic pressure)
[CS-17 (2)
→
(1)] T/M control unit [CN-157 (21)]
Parking ON
Parking ON
Fuse box [CN-39 (41)] Parking switch ON Parking solenoid [CN-71] OFF
Parking brake applied [By spring force]
Pilot cut off ON
Pilot cut off ON
Fuse box [CN-39 (41)] Pilot cut off switch ON Pilot cut off switch [CS-4 (5)
→
(4)]
I/conn [CN-05 (11)] I/conn [CN-12 (12)] Pilot cut off solenoid ON [CN-68] (activate)
Pilot cut off released
Pilot cut off OFF
Pilot cut off OFF
Fuse box [CN-39 (41)] Pilot cut off switch OFF Pilot cut off solenoid [CN-68] OFF
Pilot cut off applied
CHECK POINT
CHECK POINT
1)
1)
(1)
(1)
(2)
(2)
(3)
(3)
(4)
(4)
※
GND : Ground
2)
2)
Engine
Key switch
Check point
Voltage
Running
ON
①
- GND (parking switch input)
②
- GND (parking switch output)
③
- GND (pilot cut off switch input)
④
- GND (pilot cut off switch output)
⑤
- GND (parking solenoid)
⑥
- GND (pilot cut off solenoid)
20~25V
OFF
ON
P