7-37
This gauge indicates the fuel consumption rate and
machine load status. So that operators can be careful
with fuel economy.
The fuel consumption rate or machine load is high, the
segment is increased.
The color of Eco gauge indicates operation status.
·
White : Idle operation
·
Green : Economy operation
·
Yellow : Non-economy operation at a medium level.
·
Red : Non-economy operation at a high level.
①
②
③
Eco gauge
Eco gauge
(6)
(6)
ECO gauge
760F3CD113-1
760F3CD14-1
760F3CD15-1
760F3CD16-1
If you touch the warning sign (red icon), move to the
quick menu.
You can check the fault message and move the mainte-
nance screen by touching relevant area.
①
②
760F3CD17-1
760F3CD18-1
Machine monitoring warning
Machine monitoring warning
Warning sign (red icon) will be shown when the tem-
perature of hydraulic oil, cooling water, transmission oil
or battery voltage is not normal state.
Case of warning sign
(4)
(4)
①
②
760F3CD19-1
Communication error
Communication error
MCU could not communicate with monitor over 10 sec-
onds, error message will be show on the screen.
(5)
(5)
①
Fault and maintenance warning
Fault and maintenance warning
(3)
(3)
Icon
Description
Above 106˚C of hydraulic oil temperature
Above 105˚C of cooling water temperature
Above 107˚C of transmission oil temperature
Below 24.5 voltage of battery (for 3 minutes)
Summary of Contents for HL955