7-98
NO
NO
YES
YES
Voltage : 26~30V
Starting switch : ON
Voltage : 26~30V
Voltage : 27.5~30V
NO
2. WHEN BATTERY LAMP LIGHTS UP
WHEN BATTERY LAMP LIGHTS UP (engine is started)
·
Before carrying out below procedure, check all the related connectors are properly inserted.
·
After checking, connect the disconnected connectors again immediately unless otherwise
specified.
Cause
Remedy
Defective
controller
Disconnection in
wiring harness or
poor contact
between CN-58B
(B33) and CN-4 (18)
Disconnection in
wiring harness or
poor contact
between CN-14
(18) and alternator
terminal " 2 "
Defective alternator
Replace
Repair or replace
(after clean)
Repair or replace
(after clean)
Replace
Check voltage
between
alternator
terminal "2" and
chassis
Check voltage
between CN-4
(18) and chassis
C h e ck vo l t a g e
between CN-58B
(B33) and chassis
CN-58B
B33
CONTROLLER(MCU)
18
CN-4
ALTERNATOR
" 2 " TERMINAL
YES
Check valtage
760F7EL38
YES
20 ~ 30 V
NO
0 V