3-23
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
S
205
0
10 seconds continuous,
Boom cylinder ‘rod’ pressure Measurement Voltage > 5.3V
侑
4
10 seconds continuous,
Boom cylinder ‘rod’ pressure Measurement Voltage < 0.3V
侑
(Results / Symptoms)
1. Monitor – Boom cylinder ‘rod’ press. display failure
2. Control Function – No Boom pressure calibration function operation, workload measurement sys.
operation failure
(Checking list)
1. CN-58B(#36) – CD-81(B) Checking Open/Short
2. CN-58A(#11) – CD-81(A) Checking Open/Short
3. CN-58B(#25) – CD-81(C) Checking Open/Short
301
3
10 seconds continuous, Fuel level Measurement Voltage > 3.8V
侑
4
10 seconds continuous, Fuel level Measurement Voltage < 0.3V
侑
(Results / Symptoms)
1. Monitor – Fuel level display failure
2. Control Function – Fuel level low warning operation failure
(Checking list)
1. CN-58B (#22) – CD-02 (#2) Checking Open/Short
2. CN-58B (#25) – CD-02 (#1) Checking Open/Short
318
8
(In the startup conditions) 30 seconds continuous, Fan speed < 10 rpm in
the Remote cooling fan EPPR current reference value is in X Ma(differ by
model)
侑
(Results / Symptoms)
1. Monitor – Cooling Fan revolutions display failure
(Checking list)
1. CN-58A (#15) – CD-73 (#1) Checking Open/Short
2. CN-58A (#18) – CD-73 (#2) Checking Open/Short
339
3
10 seconds continuous,
Accel pedal position 1 voltage Measurement Voltage > 5.0 V
侑
4
10 seconds continuous,
Accel pedal position 1 voltage Measurement Voltage < 0.2 V
侑
(Results / Symptoms)
1. Monitor – Accel pedal position 1 voltage display failure
2. Control Function – Engine rpm control failure
(Checking list)
1. CN-58B(#39) – CN-162(#2) Checking Open/Short
2. CN-58A(#6) – CN-162(#3) Checking Open/Short
3. CN-58A(#8) – CN-162(#1) Checking Open/Short
G : General C : Cummins Engine application equipment S : Scania Engine application equipment
Summary of Contents for HL955