3-28
Fault code
J1939 SPN
J1939 FMI
Reason
Effect (only when fault code is active)
272
1347
3
Fuel pump pressurizing assembly 1 circuit -
Voltage above normal, or shorted to high
source. High signal voltage or open circuit
detected at the fuel pump actuator circuit.
Engine may run rough, may stop running, may
not start, or may be difficult to start.
285
639
9
SAE J1939 multiplexing PGN timeout error -
Abnormal update rate. The ECM expected
information from a multiplexed device but did
not receive it soon enough or did not receive it
at all.
At least one multiplexed device will not operate
properly.
286
639
13
SAE J1939 multiplexing configuration error -
Out of calibration. The ECM expected
information from a multiplexed device but only
received a portion of the necessary information.
At least one multiplexed device will not operate
properly.
288
974
19
Sae J1939 multiplexing remote accelerator
pedal or lever position sensor circuit - Received
network data in error. The oem vehicle
electronic control unit (VECM) detected a fault
with the remote accelerator.
Remote accelerator will not operate.
295
108
2
Barometric pressure - Data erratic, intermittent,
or incorrect. An error in the barometric pressure
sensor signal was detected by the ECM.
Engine power derate.
322
651
5
Injector solenoid driver cylinder 1 circuit -
Current below normal, or open circuit.
Current detected at injector 1 when voltage is
turned OFF.
Engine power derate.
323
655
5
Injector solenoid driver cylinder 5 circuit -
Current below normal, or open circuit.
Current detected at injector 5 when voltage is
turned OFF.
The current to the injector is shut OFF.
Engine power derate.
324
653
5
Injector solenoid driver cylinder 3 circuit -
Current below normal, or open circuit.
Current detected at injector 3 when voltage is
turned OFF.
The current to the injector is shut OFF.
Engine power derate.
325
656
5
Injector solenoid driver cylinder 6 circuit -
Current below normal, or open circuit.
Current detected at injector 6 when voltage is
turned OFF.
The current to the injector is shut OFF.
Engine power derate.
331
652
5
Injector solenoid driver cylinder 2 circuit -
Current below normal, or open circuit.
Current detected at injector 2 when voltage is
turned OFF.
The current to the injector is shut OFF.
Engine power derate.
332
654
5
Injector solenoid driver cylinder 4 circuit -
Current below normal, or open circuit.
Current detected at injector 4 when voltage is
turned OFF.
The current to the injector is shut OFF.
Engine power derate.
334
110
2
Engine coolant temperature - Data erratic,
intermittent, or incorrect. The engine coolant
temperature sensor is reading an erratic value
at initial key ON.
None on performance.
※
Some fault codes are not applied to this machine.
Summary of Contents for HL955