3-37
※
Some fault codes are not applied to this machine.
Fault code
J1939 SPN
J1939 FMI
Reason
Effect (only when fault code is active)
1993
4795
31
Aftertreatment diesel particulate filter missing -
Condition exists. The aftertreatment diesel
particulate filter in the exhaust system is not
present.
Active aftertreatment diesel particulate filter
regeneration will be disabled.
2185
3512
3
Sensor supply 4 circuit - Voltage above normal,
or shor ted to high source. High voltage
detected at 5 VDC sensor supply circuit to the
accelerator pedal position sensor.
Engine will only idle.
2186
3512
4
Sensor supply 4 circuit - Voltage below normal,
or shorted to low source. Low voltage detected
at 5 VDC sensor supply circuit to the
accelerator pedal position sensor.
Engine will only idle.
2198
641
11
VGT Actuator driver circuit - Root cause not
known.
Intermittent communication between the smart
VGT controller and the ECM has been
detected. The VGT controller is not interpreting
the J1939 message from the ECM correctly.
Possible reduced engine performance.
2272
27
4
EGR Valve position circuit - Voltage below
normal or shorted to low source. Low signal
voltage has been detected at the EGR valve
position sensor circuit
Possible reduced engine performance.
2273
411
3
Exhaust gas recirculation valve delta pressure
sensor circuit - Voltage above normal or
shorted to high source. High signal voltage
detected at the EGR differential pressure
sensor circuit.
Possible reduced engine performance.
2274
411
4
Exhaust gas recirculation valve delta pressure
sensor circuit - Voltage below normal or shorted
to low source. Low signal voltage detected at
the EGR differential pressure sensor circuit.
Possible reduced engine performance.
2288
103
15
Turbocharger 1 speed - Data valid but above
normal operating range - Least severe level.
High turbocharger speed has been detected by
the ECM.
Possible reduced engine performance.
2311
633
31
Electronic fuel injection control valve circuit -
Condition exists. Fuel pump actuator circuit
resistance too high or too low, or an intermittent
connection has been detected.
Possible reduced engine performance.
2322
723
2
Engine camshaft speed / position sensor - Data
erratic, intermittent, or incorrect.
Camshaft engine speed sensor intermittent
synchronization.
None on performance.
2349
2791
5
EGR Valve control circuit - Current below
normal or open circuit. Motor terminal or motor
coil open circuit has been detected by the ECM.
Possible reduced engine performance.