5-14
GROUP 11 INTELLIGENT POWER CONTROL SYSTEM
RH control
Main pump
Pilot pump
Engine
ECM
CAN #1
MCU
Main control valve
Pressure signal
Drive signal
Pump power
shift EPPR
One touch
decel button
Power boost
button
Horn button
Option
button
Shuttle
block
Attach flow
EPPR 1
Pressure signal
Travel
pressure
PS
Pressure signal
Switch signal
Cluster
lever
LH control
lever
SL
SR
Swing
pressure
AO
AI
Arm in/out
& Bucket in
pressure
BI
Boom up
pressure
BU
PS
PS
PS
Arm in
pressure
PS
Option
Arm 1
Boom 2
Swing
Bucket
Arm 2
Arm regen
Boom 1
Option
Travel(RH)
Travel(LH)
(Dozer)
When the requirement of pump flow rate is low, IPC mode controls pump flow rate to improve fuel
efficiency.
1.
145ZF5MS13
Condition
ୖ
1
Function
IPC mode : ON
ୖ
2
Boom up
Arm in
Not travel motion
Not swing motion
Limitation of pump flow rate : Activated
None of upper condition
Limitation of pump flow rate : Canceled
ୖ
1
#
AND condition
ୖ
2
#
IPC mode ON/OFF is selected at "Mode setup > IPC mode". See next page.