5-24
5-22-2
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
143
5
(Detection)
(When Travel EPPR Current is more than 10 mA)
10 seconds continuous, Travel EPPR drive current = 0 mA
(Cancellation)
(When Travel EPPR Current is more than 100 mA)
3 seconds continuous, Travel EPPR drive current
≥
10 mA
侑
6
(Detection)
10 seconds continuous, Travel EPPR drive current > 1.0 A
(Cancellation)
3 seconds continuous, Travel EPPR drive current
≤
1.0 A
侑
(Results / Symptoms)
1. Control Function – cruise control operation failure
(Checking list)
1. CN-246 (#2) – CN-54 (#39) Checking Open/Short
2. CN-246 (#1) – CN-51 (#40) Checking Open/Short
145
5
(Model Parameter) mounting Remote Cooling Fan EPPR
(Detection)
(When Remote Cooling Fan EPPR Current is more than 10 mA)
10 seconds continuous, Remote Cooling Fan EPPR drive current = 0 mA
(Cancellation)
(When Remote Cooling Fan EPPR Current is more than 10 mA)
3 seconds continuous, Remote Cooling Fan EPPR drive current
≥
10 mA
侑
6
(Detection)
10 seconds continuous, Remote Cooling Fan EPPR drive current > 1.0 A
(Cancellation)
3 seconds continuous, Remote Cooling Fan EPPR drive current
≤
1.0 A
侑
(Results / Symptoms)
1. Control Function – Remote fan control operation failure
(Checking list)
1. CD-52 (#1) – CN-51 (#9) Checking Open/Short
2. CD-52 (#2) – CN-51 (#14) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.