8-15
Remove valve plates (313, 314) from
valve cover (311, 312).
These may be removed in work 7, 9.
(14)
侍
If necessary, remove stopper (L, 534),
stopper (S, 535), servo piston (532) and
tilting pin (531) from pump casing (271),
and needle bearing (124) from valve
cover (311, 312).
In removing tilting pin, use a protector to
prevent pin head from being damaged.
Since loctite is applied to fitting areas of
tilting pin and servo piston, take care not
to damage servo piston.
Do not remove needle bearing as far as
possible, except when it is considered to
be out of its life span.
Do not loosen hexagon nuts of valve
cover and swash plate support.
If loosened, flow setting will be changed.
(15)
侍
侍
侍
侍
36078MP09
T h i s i s t h e e n d o f d i s a s s e m bl i n g
procedures.
(16)