4.19
Move the choke to the RUN position.
4.20
Press the decompression valve on the LPG regulator for 3 to 5 seconds.
Recoil Start
4.21
Firmly grasp the recoil handle and pull slowly until resistance is felt.
Then pull rapidly.
NOTE
: Always pull so the pull cord remains straight, if you pull the cord at an angle
it will increase cord wear and may damage the machine.
Always return the recoil cable back to the start position slowly, do not let go and allow
it to snap back.
Electric Start
4.22
Turn the ignition hey to the START position and hold there for 3 to 5 seconds.
Once the engine fires, release the key and it will automatically return to the ON position.
DO NOT hold the ignition key in the start position for periods of over 5 seconds as
this may cause damage to the machine.
If the generator fails to start, release the key, wait 60 seconds and try and again.
4.23
When the engine starts, move the choke lever to the ½ choke position until the
engine runs smoothly and then to the RUN position.
If the engine falters, move the choke lever back to the ½ choke position until the
engine runs smoothly and then back to the RUN position.