the
cooling air slots, some water will be retained in voids and crevices of the rotor and stator
winding insulation which can cause electrical shorts circuits and damage the alternator. Water
and dirt build up on the generator internal windings will eventually decrease the insulation
resistance of these windings.
6.2.4.
Cleaning the external of the generator.
6.2.4.1.
Use a damp cloth to wipe
the
exterior surfaces.
6.2.4.2.
A soft, bristle brush may be used to remove dirt, oil etc.
6.2.4.3.
A vacuum cleaner may be used to pick up loose dirt and debris.
6.2.4.4.
Low pressure air (not to exceed 25 psi) may be used to blow away dirt.
6.2.4.5.
Check cooling air slots and openings on the generator. These openings must
be kept clean and unobstructed.
6.3.
Engine Maintenance.
When working on the generator, you MUST always disconnect
the
spark plug HT cable from the
spark plug and keep
the
cable away from
the
spark plug. The fuel tap should also be in the OFF
position.
6.4.
Oil change.
Hot oil may cause burns. Allow engine to cool before draining oil. Avoid prolonged or repeated
skin exposure to used oil. Thoroughly wash exposed areas with soap.
6.4.1.
Before starting you MUST allow the engine to cool down
slightly
. While the engine is
cooling down;
6.4.1.1.
Clean area around oil drain plug.
6.4.1.2.
Remove oil drain plug and dipstick from the engine to drain oil completely
into a suitable container.
6.4.1.3.
When oil has completely drained, refit the oil drain plug and fully tighten.
6.4.1.4.
Fill
the
engine with recommended oil. SA15W40
6.4.1.5.
Wipe up any spilled oil.
6.4.1.6.
Dispose
of
used oil at a proper collection center.
6.4.1.7.
Refit the dipstick.