background image

1

1. 

SAFETY INFORMATION

Before use of the machine please read carefully this manual

Any use of the generator without reading this manual could cause hard 
damage to the machine o can hurt yourself seriously

Pay special attenction to the next:

• 

Do not use the generator in a non ventilated area

• 

Do not use the generators in wet conditions

• 

Do not start the generator when device plug.

• 

Keep at least 1 meters from flammable objects

• 

Do not refill the fuel tank with the generator running

• 

Do not smoke when fuel  refill

• 

Do not overfill the fuel

SAFETY GUARDS:

1. 

Do not use kerosene or other fuel, only use gasoline fuel. 

Clean all the excess of fuel when refill.

2. 

Any flammable or explosive product shall be kept away from 

the generator, due to the high temperature of the engine.

3. 

Install your group on a flat, horizontal surface, to avoid spilla-

ge of gasoline.

4. 

Inhalation of exhaust gas:

The exhaust gases contain poisonous carbon monoxide. Never 
use the group in a poorly ventilated area

5. 

Never touch the exhaust when the generator is running or 

after starting.

6. Short 

circuits:

Do not touch your group with wet hands. The generator is not 
waterproof, so it should not be exposed to water or snow.

7. 

Other safety points:

Yon must know how to absolutely stop your group before using it. 
Never allow someone to use the generator without having read the 
manual! Always wear a safety shoes and keep you always ready to 
clean rags. Keep children and pets away

Summary of Contents for HY2500 HY3100

Page 1: ...c HY3000I HY6000I HY7000I HY9000I Economic HY2500 HY3100 HY6000 HY7000 HY9000 Professional HY2500L S HY3100L S E HY6000L S E HY7000L S E 3 HY9000L S E 3 GASOLINE POWER GENERATORS USER MANUAL CHECK CAREFULY THIS USER MANUAL IN ORDER TO AVOID INJURIES EN ...

Page 2: ...INDEX 1 SAFETY INFORMATION 2 COMPONENTS 3 CHECK BEFORE USE 4 START OF THE ENGINE 5 STOP OF THE ENGINE 6 MAINTENANCE 7 PROBLEM SOLUTIONS 8 SPECIFICATIONS 1 2 3 4 5 5 8 9 ...

Page 3: ... the excess of fuel when refill 2 Any flammable or explosive product shall be kept away from the generator due to the high temperature of the engine 3 Install your group on a flat horizontal surface to avoid spilla ge of gasoline 4 Inhalation of exhaust gas The exhaust gases contain poisonous carbon monoxide Never use the group in a poorly ventilated area 5 Never touch the exhaust when the generat...

Page 4: ...dip 11 Fuel valve 12 Spark plug 13 Fuel tank 14 Oil drain 1 Frame 2 Muffler 3 Fuel tank 4 Air filter 5 Carburetor 6 Sockets 7 Earth connection 8 Recoil starter 9 On off swich Key contactor 10 Oil dip stick 11 Fuel valve 12 Spark plug 13 Fuel tank 14 Oil drain 2 3 3 3 4 8 8 9 9 10 10 11 11 1 1 1 1 2 2 4 4 5 5 6 6 7 7 12 12 13 13 13 14 14 2 ...

Page 5: ...4 Screw the dipstick Fuel level 1 Open the fuel cap of the fuel tank 2 Check the level of the fuel 3 Fill with fuel up to the prime fuel filter 4 Screw the fuel cap Air filter 1 Loosen the filter housing and remove the air filter 2 Remove the screw and washer and remove the filter element 3 Remove filter 4 Clean it with water do not use soup 5 Dry the filter complete and place it again in the filt...

Page 6: ...ure all appliances are in good working condition before connecting to the Group 6 If a device does not work anymore or stops suddenly stop IMMEDIATELY using the main switch and unplug the unit and check Do not forget to desconnect any device before stop the generator Stop the generator with power connected can damage the machine 7 If the value on the voltmeter is too high stop the machine and chec...

Page 7: ...e unit before any maintenance Make sure your group is located in a ventilated area to avoid carbon monoxide poisoning Clean your group with a dry cloth to prevent corrosion on it Element Every day Every month or every 20h Every 3 month or every 50h Every 6 months or every 100h Every year or every 300h Check oil level o Check Change oil o Replace o Replace Check air filter o Check Clean fuel filter...

Page 8: ...auge 5 Reposition the dipstick and tighten It is recomend to run the engine for 15min before replace the oil Oil tipe 4 stroke gasoline engine oil recommended SAE 10W 30 Air Filter 1 Undo or loosen the filter housing and remove the air filter 2 Remove the screw and washer and remove the filter element 3 Remove filter 4 Clean it with water and dry complete 5 Place the filter in the housing 6 Filx t...

Page 9: ...ilter 2 Clean fuel filter 3 Replace the O ring tank after cleaning to ensure tightness HIVERNAGE In case of prolonged storage of your generator do the following 1 Unscrew the screw of the carburetor bowl to empty its contents 2 Unscrew the oil drain screw and drain the oil from the crank case 3 Screw the oil cap after refilling with new oil 4 Fill the oil to the max 5 Slowly pull up the pitcher ha...

Page 10: ...el Open the fuel valve fill fuel in the fuel tank There is no ignition Check ignition coil and spark plug Spark plug fouled Clean the spark plug with a metal brush Thegeneratorisnot givingpower The main circuit breaker is not in ON position Place main circuit breaker to on position UP Plugs on the generator Check the plugs are in good conditions The engine speed is not enought Check with your deal...

Page 11: ...line IC210 6 5 Manual start 212 0 6 A25I 2 5 1 AVR 39 42 168 348 432 50 4 0 kW 4 4 kW 230 19 1 2x16A 6 5 7 5 68 Gasoline IC340 11 0 Manual start 337 1 1 A4I 4 1 AVR 65 68 122 257 257 50 5 0 kW 5 5 kW 230 24 2x16A 6 5 7 3 68 5 Gasoline IC390 13 0 Manual start 389 1 1 A5I 5 1 AVR 66 69 122 257 257 L W H Frequency Hz Rated Power Max Power Voltage V Current A Sockets Display FuelTank Capacity L Runnin...

Page 12: ... 177 373 436 50 4 kW 4 4 230 19 1 2x16A LED4 6 5 6 5 68 12 8 3 Gasoline IC340 11 0 Manual start 337 1 1 A4C 4 1 AVR 79 81 124 256 256 50 6 kW 6 6 kW 230 26 1x16A 1x 32A 1 LED4 6 5 6 68 12 8 3 Gasoline IC425 16 0 Manual start 420 1 1 A6C 6 1 AVR 81 84 124 256 256 L W H Frequency Hz Rated Power Max Power Voltage V Current A Sockets Display FuelTank Capacity L RunningTime under 50 Load hr NoiseLevelb...

Page 13: ... H 1 16A phase socket thermal protected 2 100W max output 10A fuse protection Frequency Hz Rated Power Max Power Voltage V Current A Sockets Display FuelTank Capacity L RunningTime under 50 Load hr NoiseLevelbehind7Meters50 Load dBA DC Output V A 2 Battery Ah EngineType Engine Power Output HP Start Method Displacement ml Oil Capacity L Alternator Rated Power kVA Power Factor Cosφ Voltage Regulatio...

Page 14: ...56 256 50 7 5 kVA 8 2 kVA 400 11 9 1x16A3P 1x161P 1 LED4 25 19 69 12 8 3 17 Gasoline IC425 15 Elec start 420 1 1 A6L 3 7 5 0 8 AVR 86 89 124 256 256 Frequency Hz Rated Power Max Power Voltage V Current A Sockets Display FuelTank Capacity L RunningTime under 50 Load hr NoiseLevelbehind7Meters50 Load dBA DC Output V A 2 Battery Ah EngineType Engine Power Output HP Start Method Displacement ml Oil Ca...

Page 15: ...7Meters50 Load dBA DC Output V A 2 Battery Ah EngineType Engine Power Output HP Start Method Displacement ml Oil Capacity L Alternator Rated Power kVA Power Factor Cosφ Voltage Regulation N w kg G W kg Loading capacity 20 40 40HQ Log data 50 2 5 kW 2 8 kW 230 12 1 2x 16A LED4 13 20 66 12 8 3 17 Gasoline IC210 6 5 Manual elec start 212 0 6 A3L 2 5 1 AVR 45 48 158 330 410 50 4 0 kW 4 4 kW 230 19 1 2...

Page 16: ...3103 Tel 86 519 85099001 Fax 86 519 85099002 Email info itc power com cn FRANCE Office Warehouse S A S United Power Europe 6 rue Ferdinand de Lesseps F 66280 SALEILLES FRANCE Tel 334 68 28 31 90 Fax 334 68 28 64 06 Email info itc power com SPAIN Office Warehouse Kat Power International S L Avda d Alguema n 6C 17771 Sta Llogaia d Alguema SPAIN Tel 34 972 538521 Fax 34 972 980537 Email info itcpower...

Reviews: