background image

2.13 

2.14 

2.15 

2.16 

2.17 

2.18 

2.19 

2.20 

2.21 

2.22 

2.23 

2.24 

DO NOT touch the compressor cylinder, cylinder head or pipe from the head to the 
tank as these may be hot and will remain so for some time after shutdown. 

DO NOT operate the compressor without all the safety guards in place. 

DO NOT attempt to move the compressor by pulling the air hose. 

DO NOT use the compressor for a task for which it was not designed. 

DO NOT deface the certification plate attached to the compressor tank. 

DO NOT operate the compressor without an air filter. 

DO NOT allow anyone to operate the compressor unless they have received full 
instruction. 

DO NOT leave the compressor unattended. 

DO NOT block the engine ventilation grills. 

DO NOT cover the compressor or restrict airflow around the machine whilst it is 
operating. 

The air tank is a pressure vessel and the following safety measures apply; 
DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any 
way. 
DO NOT strap anything to the tank. 
DO NOT subject the tank to impact, vibration or heat. 
DO NOT allow contact with abrasive or corrosive materials. 
YOU MUST drain condensation from the tank daily and inspect side walls for 
corrosion every 12 months. 

2.25 

The compressor is fitted with a standard 13amp, 230v (50Hz) plug for connection to 
a standard 13amp domestic electrical supply. 

2.26 

If the plug should need changing at any time, ensure a plug of identical specification 
is used. 

2.27 

The fuse in the plug must be replaced with one of the same rating. 

2.28 

We recommend that the compressor is connected to the mains supply via a 
Residual Current Device (RCD). 

2.29 

DO NOT use with damaged cables and only use correctly rated extension cords. 

2.30 

If in doubt, consult a qualified electrician. 

        ELECTRICAL CONNECTONS 

The pressure safety valves on Hyundai compressors have been updated to comply 

with the latest CE certification standards. The pressure release pull ring has been 

removed from the valve due to the pull ring being incorrectly used to drain the air 

from the compressor tank, causing excessive wear to this safety valve. The air and 

moisture should drained from the tank by releasing the drain valve on the bottom of 

the tank.

2.3

2

 

ALWAYS wear the appropriate Personal Protective Equipment (PPE). 

 

Summary of Contents for HY27550

Page 1: ...1...

Page 2: ...SSEMBLY 9 4 PREPERATION 10 5 STARTING PROCEDURE 11 6 STOPPING PROCEDURE 11 7 USING THE MACHINE 11 8 MAINTENANCE 12 13 9 TROUBLESHOOTING 14 10 SPECIFICATION 15 11 RECYCLING PRODUCT DISPOSAL 16 12 DECLA...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...tion before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that the air tank pressure has been vented 2 4 Only use...

Page 8: ...vibration or heat DO NOT allow contact with abrasive or corrosive materials YOU MUST drain condensation from the tank daily and inspect side walls for corrosion every 12 months 2 25 The compressor is...

Page 9: ...ed contact your dealer 3 0 Attach the air filter to the top of the motor head by screwing in to place 3 1 3 2 HY7524 and HY27550 ONLY attach the wheel kit by sliding the washer onto the axle bolt Pass...

Page 10: ...in the OFF position 4 8 Ensure that the power supply that you are going to use is operating normally 4 9 Insert the power supply cord into the power supply socket NOTE Before using the air compressor...

Page 11: ...the compressor 6 2 Reduce the pressure in the air tank through the air supply hose 7 0 7 1 7 2 7 3 7 4 7 5 7 6 To determine the correct working pressure and air flow requirements for any piece of equ...

Page 12: ...ion inside the tank 8 5 The air filter is designed to reduce noise and help prevent particulates in the air from entering and damaging the air compressor 8 6 After being used for a period of time the...

Page 13: ...ed cleaning products these could damage parts 8 15 Turn off the power and wrap the power cord around the compressor 8 16 Pull the relief valve and release all the pressure from the air tank 8 17 Clean...

Page 14: ...ce dealer The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressors specification An extension cord that is too thin or t...

Page 15: ...15 10 SPECIFICATION...

Page 16: ...ling centre 11 4 Certain products contain batteries which should not be disposed of in your domestic waste 11 5 You MUST recycle batteries in accordance with your local authority or recycling centre 1...

Page 17: ...ssel Directive And is in conformity with the applicable requirements of the following documents EN ISO 12100 2010 EN ISO 1012 1 2010 EN 60204 1 2018 EN61000 6 1 2007 EN61000 6 3 2007 A1 2011 AC 2012 E...

Page 18: ...ou make a warranty claim Full warranty terms and conditions can be found on the HYUNDAI POWER PRODUCTS website www hyundaipowerproducts co uk 15 0 Our manuals are constantly being reviewed and updated...

Page 19: ...19...

Page 20: ...mbroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom...

Reviews: