g) When engine starts, or fires, move the choke lever to the open/run position.
h) If the engine is cold, allow the engine to tick over (throttle set to slow speed) for a few
minutes before cutting, increase engine rpm to high speed setting before use. Please note
that the centrifugal clutch may slip which will cause excessive wear if the machine is used
at speeds below half throttle.
NOTE
•
If the generator stops and cannot restart, check the fuel switch/choke firstly. Then
check the fuel level. If the oil indicator is on, adding the oil before restart.
7.1
The generator ground terminal is connected to the frame of the generator, the metal non-
current carrying parts of the generator and ground terminal of each receptacle. Before using
the ground terminal consult a qualified electrician, electrical inspector or local agency having
jurisdiction for local codes or ordinance that apply to the intended use the generator.
7.2
DO NOT
connect to the building's electrical system, in order to avoid the electric shocks and
fires
7.3
Connection for standby power to building electrical system must be made by a qualified
electrician. The connection must isolate the generator from the utility power, and must comply
with all the applicable laws and electrical regulations. A transfer switch must be used.
7.4
Due to high mechanical stresses, only tough rubber-sheathed flexible cable
(in accordance
with IEC 60245-4)
or the equivalent should be used
7.5
For continuous operation, do not exceed the rated out-put power of generator.
7.6
DO NOT
connect the generator to household circuit. This could cause damage to the
generator or to electrical appliances in the house.
7.
GENERATOR USE