NO SPARK AFTER SERVICE
16.4
POSSIBE CAUSE
1)
Faulty engine switch.
POSSIBLE CORRECTIVE ACTION
1)
Contact your dealer.
LOW COMPRESSION
16.5
POSSIBE CAUSE
1)
Serious internal engine damage or faulty valves.
POSSIBLE CORRECTIVE ACTION
1)
Contact your dealer.
ENGINE LACKS POWER OR RUNS UNEVENLY
AIR FILTER
16.6
POSSIBE CAUSE
1)
Clogged Air Filter.
POSSIBLE CORRECTIVE ACTION
1)
Clean and or replace as required.
FUEL SYSTEM
16.7
POSSIBE CAUSE
1)
Machine stored incorrectly with regards to emptying fuel system.
POSSIBLE CORRECTIVE ACTION
1)
Check and clean fuel tank of sludge, fuel lines and carburetor. Refill with fresh fuel.