PAGE 19
Rev 2
-
Temperature in operating ambient: 0°C +35°C.
-
DO NOT aim jets of water or inflammable liquids on the compressor.
-
DO NOT place inflammable objects near the compressor.
-
During down-times, turn the pressure switch to position “0” (OFF).
-
Never aim the air jet at people or animals (fig. 34)
-
DO NOT transport the compressor while the tank is pressurised.
-
Be careful with regard to some parts of the compressor such as the head and delivery tubes, as
they can reach high temperatures. DO NOT touch these parts to avoid burns.(fig. 18 - 19).
-
Transport the compressor, lifting or pulling it with the appropriate grips or handles (fig. 4 - 6).
-
Keep children and animals well away from the machine operating area.
-
If using the compressor for painting:
DO NOT work in closed environments or near to naked flames.
Make sure there is adequate exchange of air at the place of work.
Protect your nose and mouth with an appropriate mask. (fig. 35).
-
If the electrical cable or plug are damaged, do not use the compressor and contact an
authorised service centre to replace the faulty element with an original spare part.
-
If the compressor is located on a shelf or on a top above floor height, it must be secured to
prevent it falling while in operation.
-
DO NOT put objects or your hands inside the protective grilles to avoid injury to yourself or
damaging the compressor. (fig. 36)
-
When you have finished using the compressor, always remove the plug from the power socket.
Hints for efficient operation.
For efficient operation of the machine at full continuing load and maximum operating pressure ,
make sure the temperature of the work environment indoors does not 25°C.
We advise you to use the compressor at 70% maximum duty per hour, as this make for efficient
operation of the product in the long term.
5.16
Storing the compressor.
5.16.1
During the time that the compressor is unpacked store it in a dry place and a
temperature of b5°C and + 45°C and sheltered away from the weather.
5.16.2
For the whole time that the compressor is not used after unpacking it, while waiting
to start it up place sheets over it to protect it from dust, which may settle on the
components.
5.16.3
The oil is to be replaced and the operational efficiency of the compressor is to be
checked if it is not used for long periods.
5.17
Pneumatic connections.
5.17.1
Make sure you use pneumatic tubes for compressed air with maximum
characteristics that are adequate for the compressor. DO NOT repair faulty tubes.