11
NOTE
Before using the air compressor for the first time, complete a test run as follows:
4.10
Turn the power switch to the OFF Position.
4.11
Check the oil level is in the red circle of the glass sight window.
4.12
Plug the power supply cord into a power supply socket.
4.13
Start the air compressor by turning the power switch to the ON position.
4.14
The pressure gauge reading will slowly rise as pressure increases inside the air tank.
4.15
When the gauge reading reaches working pressure, the pressure switch will
automatically turn the power off.
This indicates the compressor is working normally.
4.16
Turn the power switch to the OFF position, unplug the power supply cord and release
the air in the tank by pulling the safety valve.
4.17
If the compressor is not working properly, the pressure gauge will indicate that there
is a decrease in pressure in the air tank.
If there is an air leak from the compressor the pressure in the air tank decreases, the
pressure switch resets and the motor automatically turns back on.
5.0
Check that the power switch is in the OFF position.
5.1
Attach the air hose to the ¼” quick disconnect coupler.
5.2
Close the drain valve and ensure the air filter is installed.
5.3
Close the drain valve.
5.4
Check the oil level.
5.5
Plug the compressor in to a working plug socket.
5.6
Turn the power switch to the ON position.
5.7
Allow the motor to run and fill the tank until the motor turns off.
5.8
To regulate the air flow: While the air compressor is running, turn ON your tool and
turn the regulator knob to the right increasing the pressure.
Turn the pressure up until the desired pressure is reached.
5.9
Operate air tool normally.
TEST RUN
5. STARTING PROCEDURE