3.7 

Keep the voltage within ±4% of the rated value. 

3.8 

Insert the power supply cord into the power supply socket. 

NOTE

Before using the air compressor for the first time, complete a test run as follows.

 

3.9 

Move the power switch to the OFF position. 

3.10 

Check the oil level is in the red circle of the glass sight window. 

3.11 

Plug the power supply cord into a power supply socket. 

3.12 

Start the air compressor by moving the power switch to the ON position. 

3.13 

The pressure gauge reading will slowly rise as pressure increases inside the air tank. 

3.14 

When the gauge reading reaches working pressure, the pressure switch will 
automatically turn the power off. 
This indicates the compressor is working normally. 

3.15 

Move the power switch to the OFF position, unplug the power supply cord and release 
the air in the tank by pulling the safety valve. 

3.16 

If the compressor is not working properly, the pressure gauge will indicate that there 
is a decrease in pressure in the tank. 
If there is an air leak from the compressor, the pressure in the air tank decreases, the 
pressure switch resets and the motor automatically turns back on. 

4.0 

Check that the power switch is in the OFF position. 

4.1 

Attach the air hose to the ¼” quick disconnect coupler. 

4.2 

Close the drain valve and ensure the air filter is installed. 

4.3 

Close the drain valve. 

4.4 

Check the oil level. 

4.5 

Plug the compressor in to a working plug socket. 

4.6 

Move the power switch to the ON position. 

4.7 

Allow the tank motor to run and fill the tank until the motor turns off. 

4.8 

To regulate the air flow: While the air compressor is running, turn ON your tool and 
turn the regulator knob to the right, increasing the pressure. 
Turn the pressure up until the desired pressure is reached. 

4.9 

Operate the air tool normally. 

        TEST RUN 

4. STARTING PROCEDURE

Summary of Contents for HY3100P

Page 1: ...1 HY3150S HY3200S HY3100P...

Page 2: ...RATION 9 10 4 STARTING PROCEDURE 10 5 STOPPING PROCEDURE 11 6 USING THE MACHINE 11 7 MAINTENANCE 11 12 8 TROUBLESHOOTING 13 9 SPECIFICATION 14 10 RECYCLING PRODUCT DISPOSAL 15 11 DECLARATION OF CONFOR...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...re that the compressor is in good order and condition before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that th...

Page 8: ...on or heat DO NOT allow contact with abrasive or corrosive materials YOU MUST drain condensation from the tank daily and inspect side walls for corrosion every 12 months Correct Personal Protective Eq...

Page 9: ...r cannot move while in operation 3 3 If the surface is in a raised position make sure the compressor cannot fall securing it in a suitable way 3 4 Check the oil level sits in the red circle of the oil...

Page 10: ...e air in the tank by pulling the safety valve 3 16 If the compressor is not working properly the pressure gauge will indicate that there is a decrease in pressure in the tank If there is an air leak f...

Page 11: ...anti clockwise 6 6 DO NOT allow moisture to accumulate in the tank as this will corrode the inside of the tank and affect the pressure rating of the tank WARNING Service and maintenance must be perfor...

Page 12: ...ny house or connection will reduce the air compressors performance 7 12 To test for leaks spray a small amount of soapy water on the area suspected of leaking If soap bubbles appear replace the broken...

Page 13: ...The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressors specification An extension cord that is under rated or too long...

Page 14: ...90 9 SPECIFICATION Model HY3200S Power kw hp 2 2 3 Displacement L min 396 CFM 14 Pressure bar psi Pump Speed rpm 1050 Tank Capacity L 200 Dimensions mm LxWxH Weight kg 10 145 105 1380 x 560 x 910 Mode...

Page 15: ...ling centre 10 4 Certain products contain batteries which should not be disposed of in your domestic waste 10 5 You MUST recycle batteries in accordance with your local authority or recycling centre 1...

Page 16: ...y with the applicable requirements of the following documents EN ISO 12100 2010 EN ISO 1012 2010 EN 60204 1 2006 A1 2009 AC 2010 EN 6100 6 1 2007 EN 6100 6 3 2007 A1 2011 AC 2012 EN 6100 3 2 2014 EN 6...

Page 17: ...WARRANTY Proof of purchase will be required before you make a warranty claim Full warranty terms and conditions can be found on the HYUNDAI POWER PRODUCTS website www hyundaipowerproducts co uk 14 MA...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: