background image

13 

PROBLEM 

POSSIBLE CAUSE 

POSSIBLE SOLUTION 

Pressure drop in the tank 

Air leaks at the connections 

Let the compressor build up 
pressure in the tank to 
maximum pressure if possible. 
Brush soapy water on the air 
connections and look for air 
bubbles. Tighten leaky 
connections. If the problem 
persists, contact your service 
dealer 

The unloader valve leaks when 
the compressor is idle 

Unloader valve seal is 
defective 

Let the air in the air tank flow 
out until all the pressure is 
released. Then remove the 
unloader valve plug and clean 
the valve seal. If necessary, 
replace the seal and then 
reinstall 

The compressor stopped and 
won’t restart 

The thermal protector turned 
on because the motor is 
overheating 

Check the main voltage 
corresponds to the air 
compressor specifications. An 
extension cord that is under 
rated or too long can cause the 
motor to overheat. 
Allow the motor to cool down 

Motor windings have burnt out 

Contact your service dealer 

The motor does not start or 
starts slowly 

Low voltage supply to the 
motor 

Check that the main voltage 
corresponds to the air 
compressors specification. 
An extension cord that is under 
rated or too long can cause 
voltage drop. Use a heavy duty 
extension cord. 
Ensure that the air compressor 
is plugged in to a fully 
functioning power outlet 

The compressor is noisy 

Compressor head gasket or 
reed valve is faulty 

Stop the compressor and 
contact your service dealer 

The compressor does not 
reach maximum pressure 

Compressor head gasket or 
reed valve is faulty 

Stop the compressor and 
contact your service dealer 

The compressor does not 
seem to deliver as much air as 
it did when new and/or the 
compressor shuts off with a 
much shorter time period 

The pressure switch needs 
adjusting 

Stop the compressor and 
contact your service dealer 

The tank is full of water due to 
condensation 

Open the drain valve and 
release the water from the tank 

The motor pump unit does not 
stop when the tank pressure 
reaches maximum working 
pressure 

Pressure switch defective or 
requires adjusting 

Stop the compressor and 
contact your service dealer 

8. TROUBLESHOOTING

Summary of Contents for HY3100P

Page 1: ...1 HY3150S HY3200S HY3100P...

Page 2: ...RATION 9 10 4 STARTING PROCEDURE 10 5 STOPPING PROCEDURE 11 6 USING THE MACHINE 11 7 MAINTENANCE 11 12 8 TROUBLESHOOTING 13 9 SPECIFICATION 14 10 RECYCLING PRODUCT DISPOSAL 15 11 DECLARATION OF CONFOR...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...re that the compressor is in good order and condition before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that th...

Page 8: ...on or heat DO NOT allow contact with abrasive or corrosive materials YOU MUST drain condensation from the tank daily and inspect side walls for corrosion every 12 months Correct Personal Protective Eq...

Page 9: ...r cannot move while in operation 3 3 If the surface is in a raised position make sure the compressor cannot fall securing it in a suitable way 3 4 Check the oil level sits in the red circle of the oil...

Page 10: ...e air in the tank by pulling the safety valve 3 16 If the compressor is not working properly the pressure gauge will indicate that there is a decrease in pressure in the tank If there is an air leak f...

Page 11: ...anti clockwise 6 6 DO NOT allow moisture to accumulate in the tank as this will corrode the inside of the tank and affect the pressure rating of the tank WARNING Service and maintenance must be perfor...

Page 12: ...ny house or connection will reduce the air compressors performance 7 12 To test for leaks spray a small amount of soapy water on the area suspected of leaking If soap bubbles appear replace the broken...

Page 13: ...The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressors specification An extension cord that is under rated or too long...

Page 14: ...90 9 SPECIFICATION Model HY3200S Power kw hp 2 2 3 Displacement L min 396 CFM 14 Pressure bar psi Pump Speed rpm 1050 Tank Capacity L 200 Dimensions mm LxWxH Weight kg 10 145 105 1380 x 560 x 910 Mode...

Page 15: ...ling centre 10 4 Certain products contain batteries which should not be disposed of in your domestic waste 10 5 You MUST recycle batteries in accordance with your local authority or recycling centre 1...

Page 16: ...y with the applicable requirements of the following documents EN ISO 12100 2010 EN ISO 1012 2010 EN 60204 1 2006 A1 2009 AC 2010 EN 6100 6 1 2007 EN 6100 6 3 2007 A1 2011 AC 2012 EN 6100 3 2 2014 EN 6...

Page 17: ...WARRANTY Proof of purchase will be required before you make a warranty claim Full warranty terms and conditions can be found on the HYUNDAI POWER PRODUCTS website www hyundaipowerproducts co uk 14 MA...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: