background image

15 

 

 

 

 

10.0   

We do not offer a take back scheme for the recovery of Waste Electrical Electronic 

 

 

Equipment (WEEE) & Batteries. 

 

 

Instead the responsibility to dispose of WEEE and or Batteries is passed on to you by 

 

 

us. 

 

 

So when it becomes necessary to dispose of your machine you must take it to your 

 

 

local Civic Amenity Site. 

 

 

For further information please contact your local Authority for disposal advice.

 

10.1   

You MUST make sure that all unused oil and fuel is disposed of correctly either 

 

 

beforehand or at your local Civic Amenity Site. 

 

 

Under NO circumstances must any fuel or oil be put down drains.

 

10.2   

Certain products contain WEEE waste which should be disposed 

 

 

of in your domestic waste. 

10.3   

You MUST recycle WEEE in accordance with your local authority or 

 

 

recycling centre. 

10.4   

Certain products contain batteries which should not be disposed of 

 

 

in your domestic waste. 

10.5   

You MUST recycle batteries in accordance with your local authority or recycling 

 

 

centre. 

10.6   

Unwanted packaging and materials should be stored and taken to a recycling centre 

 

 

so it can be disposed of in a manner which is compatible with the environment. 

10.7   

The following symbol means that you should ‘Reduce – Reuse -  

 

 

Recycle’

 

 

 

10.8   

We are a member of the VALPAK National Compliance Scheme and our registration 

 

 

number is RM08660. 

10.9   

For further information about disposal please contact your Local Authority. 

10.10   

You can also get more advice and guidance about recycling at the following website 

 

 

http://recycle-more.co.uk

 

10.11   

Should you pass this product on to another user either sold or loaned, you MUST 

 

 

pass on this user manual. 

 

 

This will make sure that all other users can use and maintain this machine safely. 

 

 

 

 

 

 

 

        10. RECYCLING AND PRODUCT DISPOSAL 

Summary of Contents for HY3150S

Page 1: ...1...

Page 2: ...RATION 9 10 4 STARTING PROCEDURE 10 5 STOPPING PROCEDURE 11 6 USING THE MACHINE 11 7 MAINTENANCE 11 12 8 TROUBLESHOOTING 13 9 SPECIFICATION 14 10 RECYCLING PRODUCT DISPOSAL 15 11 DECLARATION OF CONFOR...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...re that the compressor is in good order and condition before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that th...

Page 8: ...ssure vessel and the following safety measures apply DO NOT tamper with the safety valve DO NOT modify or alter the tank in any way DO NOT strap anything to the tank DO NOT subject the tank to impact...

Page 9: ...r cannot move while in operation 3 3 If the surface is in a raised position make sure the compressor cannot fall securing it in a suitable way 3 4 Check the oil level sits in the red circle of the oil...

Page 10: ...e air in the tank by pulling the safety valve 3 16 If the compressor is not working properly the pressure gauge will indicate that there is a decrease in pressure in the tank If there is an air leak f...

Page 11: ...anti clockwise 6 6 DO NOT allow moisture to accumulate in the tank as this will corrode the inside of the tank and affect the pressure rating of the tank WARNING Service and maintenance must be perfor...

Page 12: ...ny house or connection will reduce the air compressors performance 7 12 To test for leaks spray a small amount of soapy water on the area suspected of leaking If soap bubbles appear replace the broken...

Page 13: ...The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressors specification An extension cord that is under rated or too long...

Page 14: ...4 Model HY3150S Power kw hp 2 2 3 Displacement L min 300 CFM 10 6 Pressure bar psi 10 115 Rotating Speed rpm 1050 Tank Capacity L 150 Dimensions mm LxWxH 1310 x 500 x 880 Weight kg 117 9 SPECIFICATION...

Page 15: ...ling centre 10 4 Certain products contain batteries which should not be disposed of in your domestic waste 10 5 You MUST recycle batteries in accordance with your local authority or recycling centre 1...

Page 16: ...utdoors Equipment Category Electric Air Compressor Product Name Model HY3150S Type Serial No Electric Air Compressor Net Installed Power 2 2Kw The technical document is kept by Roland Llewellin Genpow...

Page 17: ...ine for the Manufacturer s Warranty please visit https hyundaipowerequipment co uk 13 1 For full Warranty terms and conditions please visit https hyundaipowerequipment co uk support waranty informatio...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: