11
2.6
To fill with fuel, remove the fuel filler cap.
2.7
Fill with 12.5 litres of fresh unleaded petrol.
DO NOT
mix fuel with the oil.
2.8
DO NOT
overfill, fill to the upper limit mark or leave a 25mm gap between the fuel and
the top of the fuel tank.
2.9
Wipe up any spills immediately.
2.10
Refit the fuel filler cap securely.
2.11
This generator is supplied with a ‘floating earth’.
2.12
It I therefore extremely important that you only use the generator to power equipment
in the following permutations;
1 or more class 2 equipment or;
1 piece of class 1 equipment or;
1 or more Class 2 equipment and 1 piece of Class 1 equipment.
2.13
Class 1 equipment uses an earth wire.
2.14
Class 2 equipment (also known as double insulated) does
NOT
use an earth wire and
will have the following symbol on it.
2.15
If the generator is to be used in a more permanent location, then it is advisable to
connect the generator to an earth rod or earth point.
DO NOT
put an earth rod into the ground until you have checked that it is safe to do so.
We strongly suggest that you contact a qualified electrician to assist you with this.