12
2.17
Use copper wires 10mm
2
or higher to connect to the vehicle battery.
2.18
Keep the distance from the battery to the generator as short as possible.
2.19
The generator on/off switch should be easy to access and near the remote LCM
controller.
IMPORTANT
DO NOT
overload the generator.
DO NOT
overload individual output sockets.
If the current rating of any socket is exceeded, that generator will shut down AC
power and show as AC OFF on the remote LCM controller.
NOTE
Connect all electrical loads in the
OFF
position then turn
ON
for operation.
Turn all electrical loads
OFF
and disconnect from the generator before stopping the
generator.
Exceeding the generators wattage/current capacity could damage the generator
and/or the electrical devices connected to it.
DO NOT
exceed the generators wattage/current capacity.
3.0
Turn the main generator power switch to the ON position.
3.1
Press the Power ON button on the remote LCM controller to start the generator.
3.2
The remote LCM controller should display AC OFF.
4. STARTING PROCEDURE
WIRING DIAGRAM