<<19>>
●
For continuous operation, do not exceed the
rated out-put power of generator.
●
Do not make parallel connection with other
generators.
●
Do not connect an extension to the exhaust
pipe.
●
When an extension cable is required, be sure
to use a tough rubber sheathed flexible cable
(according to IEC245 or equivalent
standards). The maxmin length of the
2
extension cable: 60m for cable of 1.5mm ;
2
100m for cable of 2.5mm .
●
Keep away from other electric cables or wires.
WARNING
NOTE
■
The
DC
receptacle can be used while the
AC
power is in use. If use both at same time, be
sure not to exceed the total power for
AC
and
DC.
■
Most of motor appliances
require more than
their rated wattage, when starting.
6.1) DC Application
The
DC receptacle, 15-30V
under
no
-
load
condition,
may be used for charging 12V battery only.
NOTE
■
ECON
.
SW
In DC operation, turn the
to the
“OFF” ( ) position.
6.1.1) Disconnect the vehicle battery ground cable
from the negative
battery terminals.
(-)
6.1.2) Connect the DC
to battery
terminals
terminals with the charging cable
.
CAUTION
Connect red lead to positive
battery terminal
(+)
and black lead to negative
battery terminal.
(-)
6.1.3) Turn
to “OFF” ( ) position and
ECON
.
SW
,
then start engine
.