5-24
GROUP 3 ELECTRICAL SYSTEM
1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT
APPEAR
Â
Before disconnecting the connector, always turn the starting switch OFF.
Â
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No. 2.
Â
After checking, insert the disconnected connectors again immediately unless otherwise specified.
YES
NO
Check voltage
between CN-56
(2) and chassis
CLUSTER
POWER IG(12V)
2
CN-56
1
FUSE
NO.2
10 ~ 12.5V
YES
Check voltage
NO
0V
3
17
Starting switch : ON
Voltage : 10~12.5V
Cause
Remedy
Defective cluster
Disconnection in
wiring harness or
poor contact
between CN-56
(1) and fuse No.2.
Replace
Repair or
replace
(After clean)
R35Z75TS10