5-30
7. WHEN FUEL GAUGE DOES NOT OPERATE(Check warning lamp ON/OFF)
Â
Before disconnecting the connector, always turn the starting switch OFF.
Â
Before carrying out below procedure, check all the related connectors are properly inserted.
Â
After checking, insert the disconnected connectors again immediately unless otherwise specified.
CN-2
CLUSTER
CN-56
10
FUEL SENDER
CD-2
11
3
2
1
1
2
3
Cause
Remedy
Disconnection in
wiring harness
Defective cluster
Defective fuel
sensor
Defective cluster
Check and repair
Replace
Replace
Replace
YES
YES
Starting switch : ON
Does the gauge
move up and
down at lamp
check?
Is resistance
between CN-56
(11) and chassis
over 1k
̫
?
Starting switch : OFF
Disconnect CN-51
Disconnect CD-2
See Table
Check resistance
between CD-2(2)
and (3)
YES
NO
NO
NO
Red range
R35Z75TS16
Temperature
Empty
1/2
Check Table
Item
Unit Resistance(
̫
)
90 38
Full
10