EN - 26
Outdoor Thermo Sensor Unit Registration Procedure:
• The main unit automatically starts receiving transmission from Outdoor Thermo Sensor for
outdoor temperature after are Weather condition setting .
• The thermo sensor will automatically transmit temperature to the main unit after batteries
inserted. Batteries compartment (D7) of thermo sensor is locating behind the back cover,
unscrews to open.
• Press “ TX “ button (D6) on the thermo sensor unit to transmit temperature to the main unit
manually. The main unit gives a “beep” sound if it received the temperature.
Display outdoor temperature :
• Hold “ Search” button (B5) for 3 seconds to cancel unused channel manually. It will
automatically register a new channel again if a new channel is received.
If there is no temperature displayed in existing channel ( “ - - . –“ is displayed on the LCD ),
hold “Search” button (B5) for 3 seconds to cancel that channel and will receive
the channel again (“Beep” sound can be heard.). Then, press “ TX “ button (D6)
on the remote sensor unit to transmit signal to the main unit manually.
• The trend pointer displayed on the LCD indicates the trend of the outdoor temperature.
“
” indicates the outdoor temperature is increasing.
“
” indicates the outdoor temperature is steady.
“
” indicates the outdoor temperature is decreasing.
Maximum/Minimum For Indoor Humidity and IN&OUT door temperature Recording Functi-
on:
• Press “MAX/MIN” button (B6) to show the maximum or minimum Record reading.
“
MAX
” is shown on the LCD if maximum record is shown.
“
MIN
” is shown on the LCD if minimum record is shown.
• Hold “MAX/MIN” button (B2) for 3 seconds to clear the recorded maximum and minimum
reading.
Indoor Humidity display and Comfort Icon
• Indoor humidity and Comfort Icon display on A5.
“Dry” indicate the indoor humidity <40%
“Comfort” indicate the indoor humidity is between 40%and70%, the indoor temperature is
between 20C and 26C
“Wet” indicate the indoor humidity >=70%
Thermometer:
• Press “-(°C / °F)” button (B8) to select Indoor/Outdoor Temperature in Celsius mode/ Fahrenheit
mode.
• If the temperature is out of the measurable range, LL.L ( beyond the minimum temperature)
or HH.H (beyond the maximum temperature) will be shown on the LCD.
The use of 1.5m cord Temperature Probe:
Insert the probe plug (D8) on the right hand side of the Thermo Sensor Unit.
Put the metal casing outside and leave the Thermo Sensor Unit in an indoor area to avoid free
-
zing up the battery when the outdoor temperature is below -20 °C.
Always use the temperature probe to sense the temperature when the temperature is between
the following range: -50 °C ~ 0°C and +50°C ~ + 70°C
•
•
•
Summary of Contents for WS 1850
Page 30: ...Pozn mky Notes Notatky...
Page 31: ...Pozn mky Notes Notatky...
Page 32: ...Seoul Korea...