New R-Line Refuse Collection Micro
User Manual RCM10
52
4.11
Lubricants
Lubricants to be used
The table below shows the lubricants recommended by HYVA MECHANICS
(CHINA) CO.,LTD
TYPE OF
LUBRICANT
RECOMMENDED PRODUCTS
Oil
Hydraulic oil, pouring in the quantity necessary to fill the gap from the level you
observed earlier and checking this via the tube (T). Recommendations for annual
average temperature over 20
℃
: Shell HM 46 anti-abrade oil.
Recommendations for annual average temperature below 20
℃
: Shell HM 32 anti-
abrade oil.
Grease
Grease 1-2-3
Table 5-5
4.12
Maintenance operating instructions
Introduction
ATTENTION
Before carrying out any operations, check the machine is safely
stopped, disconnecting it from the power supply and switching
off the vehicle engine.
Safety regulations for
accessing the upper
parts of the machine
ATTENTION
When it is necessary to access the upper parts of the line, you
must only use lifting means suitable for the operations to be
carried out and complying with the current regulations
regarding health and safety in the workplace.