User Manual
BOP HD8 / BOP HD16
Ref.: IR1212828 A 21.08.2009
Edition 1.0
Page 28/87
I + M E A C T I A G m b H
3.6
C
ONNECTION OF THE
P
OWER SUPPLY
Specification of the power supply
Input voltage 10-32 VDC (typical 12VDC or 24VDC)
max. current: 8A at 12VDC
Connection at
+
plug 2 - pin 1
-
plug 2 - pin 3
3.7
I
GNITION
C
ONNECTION
After the installation and the commissioning the BOP HD can be switched on/switched off
by the ignition. Precondition is that before the BOP HD is switch to the mode >PAUSE< or
>RECORD< by the key-switch.
Specification ignition signal
Steady signal with input voltage 10-32 VDC (typical 12VDC or 24VDC)
Connection at
Ignition on
plug 2 - pin 2
Ground
plug 2 - pin 3
3.8
C
ONNECTION OF DOOR CONTACT
,
REVERSE GEAR
,
ALARM SWITCH
,
ETC
.
Signals which should be evaluated and/or recorded by the BOB HD must be connected to
the digital inputs. Three signals can be used to activate the BOP HD (wakeup function).
Specification wakeup signal (BOP HD switches to >PAUSE< or >RECORD<)
Steady signal with input voltage 10-32 VDC (typical 12VDC or 24VDC)
Connection at
Wakeup
plug 2 - pin 12, 13 or 14
Masse
plug 2 - pin 21