CABLINE-CX II PLUG Without Cover Assembly Manual
Document No.
ASM-17011
15
/
16
Confidential C
②
SHELL-A,B と Ground Bar を半田コテにて全箇所半田付けする。 (Fig.12,13
◆
部)
半田コテの条件は、8 頁参照。
SHELL-A, B and Ground Bar are soldered with the soldering iron at all designated points.
(Fig.12,13
◆
point)
Conditions of Soldering iron refer to sheet 8.
Fig.12 Soldering of Shell-A and Ground Bar
Fig.13 Soldering of Shell-B and Ground bar/ Shell-A and Shell-B
※半田付け時は、コネクタに必要以上の力で半田コテを押し当てないで下さい。
コネクタ変形の原因となります。
When soldering, do not press the soldering iron against the connector with excessive force.
There is possibility of connector deformation.
◆Points
◆
Points
Top view
Bottom view
Top solder leaking
Bottom solder leaking