background image

 

 

 

1

  / 

9

 

Confidential C

 

                                                                            I-PEX Inc.                                                            QKE-DFFDE09-04 REV.8 

Document No.

ASM-13003 

 
 
 

 
 
 
 
 

 

 
 
 
 
 

CABLINE

®

-VSF 

Part No. 20645-0**T-01, 3049-0**1 

 

Assembly Manual

 

S19531 

September 13, 2019 

T.Onishi 

T.Masunaga 

H.Ikari 

S14534 

December 22, 2014 

H.Aoki 

J.Tateishi 

E.Kawabe 

S14425 

October 16, 2014 

H.Ikari 

J.Tateishi 

E.Kawabe 

S14257 

June 30, 2014 

H.Aoki 

J.Tateishi 

E.Kawabe 

Rev. 

ECN 

Date 

Prepared by 

Checked by 

Approved by 

Summary of Contents for CABLINE-VSF

Page 1: ...645 0 T 01 3049 0 1 Assembly Manual 4 S19531 September 13 2019 T Onishi T Masunaga H Ikari 3 S14534 December 22 2014 H Aoki J Tateishi E Kawabe 2 S14425 October 16 2014 H Ikari J Tateishi E Kawabe 1 S...

Page 2: ...20645 0 T 01 PLUG SHELL Without LOCK BAR 3049 0 1 3 Work procedures 3 1 Connector delivery state and cautions in treating connector SHELL ASS Y 1 SHELL ASS Y is delivered to the tray in the packed st...

Page 3: ...ine green line as shown in photo 2 by a scissors for metal SHELL 45 1 5 Hold the center of SHELL and cut it off from Notch by 45 deg of reciprocating work When it does not be cut try again this recipr...

Page 4: ...f Notch 8 Caution Please do not pull forcibly SHELL and Carrier as shown in Photo 8 Red arrow direction it cause the burr and transformation Photo 6 Bottom side view Photo 7 Upper side view Photo 8 Cu...

Page 5: ...S Y With LOCK BAR and SHELL Without Lock Bar perform similar procedure 3 2 FPC Assembly of FPC 3 FPC SHELL Please set FPC to SHELL horizontally as shown in Fig 3 4 FPC Please do not insert FPC that th...

Page 6: ...L undersurface Fig 5 FPC inserting method 2 1 Caution 1 FPC 6 FPC Please insert FPC horizontally If FPC is slanted as shown in Fig 6 it cause the breakage of FPC Fig 6 FPC insertion Bad example 2 FPC...

Page 7: ...A It confirms whether FPC is being assembled normally Check SHELL Lock condition to judge that FPC is assembled normally Fig 7 point and View A Fig 7 Confirmation of FPC assembly Point View A Point Vi...

Page 8: ...n If it need to increase the FPC holding force from SHELL perform the FPC soldering When perform the FPC soldering FPC need the soldering part as shown in Fig 8 Fig 8 Soldered part of FPC SHELL FPC 9...

Page 9: ...9 9 Confidential C X SOLDERING SOLDERING OK Sufficient solder 0 10MAX FPC SHELL Please solder until the soldered part of FPC contacts SHELL red line part NG Insufficient solder Fig 9 Sufficient solde...