CABLINE-VSF CONN. Instruction Manual

 

Document No. 

HIM-13010 

 

 
 

 

11

  / 

12

 

Confidential C                                                                                                                                                                                                   

【コネクタ取扱の注意】

(CAUTION IN CABLE CONNECTOR HANDLING.) 

FPC

を垂直方向及び上煽り方向に引っ張ると、下写真の様に基板側コネクタのシェルが変形したり、

FPC

 

SHELL

から抜ける恐れがありますので行わないで下さい。

 

また、

LOCK BAR

に関しても同様に、垂直方向に引っ張らないようにお願いいたします。

 

In case the FPC is pulled to the vertical direction

 

or slanted direction, SHELL of the receptacle connector can deform or FPC might pull out 

from plug. Please don’t pull FPC vertically or with slanted angle, LOCK BAR should not be pulled to the vertical direction. 

 

                                                         

             

 

     

       

         

 

 

 

 

 

垂直荷重

  / Vertical load 

       

       

   

 

   

                                                                                                     

 

                     

シェル変形

  / Shell deformation.                                FPC

抜け

  / FPC pull out from SHELL 

 

 

 

 

 

 

 

 

 

LOCK BAR

垂直荷重

  / LOCK BAR vertical load 

 

 

Shell bend up 

Summary of Contents for CABLINE-VSF

Page 1: ...3 REV 8 CABLINE VSF CONN Part No PLUG 20645 0 T 01 3049 0 1 RECEPTACLE 20455 0 E Instruction Manual 2 S14534 December 22 2014 H A E K 1 S14257 June 30 2014 H I E K 0 S13474 December 10 2013 H Aoki J T...

Page 2: ...E VSF PLUG Part No 20645 0 T 01 SHELL ASS Y With LOCK BAR 3049 0 1 SHELL Without LOCK BAR Fig 1 SHELLASS Y With LOCK BAR Fig 2 SHELL Without LOCK BAR FPC assembly state FPC assembly state PCB side con...

Page 3: ...matched 3 Fig 3 2 How to mate 4 FPC As shown in Fig 4 push FPC horizontally until it is locked 4 Fig 4 SHELL LOCK BAR For the connector SHELL Without LOCK BAR FPC Insert FPC to the connector horizont...

Page 4: ...NE VSF CONN Instruction Manual Document No HIM 13010 4 12 Confidential C Cautions 5 When you push one end it might cause half mating Fig 5 5 Fig 5 NG There is gap NG 1 Push the one side 2 Push the one...

Page 5: ...er there is space between mating confirmation surfaces 6 Fig 6 LOCK BAR SHELL After mated push LOCK BAR to the PCB side and lock it to SHELL of the PCB side connector 7 Fig 7 Contents of confirmation...

Page 6: ...OCK BAR When mating in case you mate the connector pushing LOCK BAR as shown in Fig 10 there are possibilities to cause LOCK BAR deformation or the rotation axis dropping out from the connector Please...

Page 7: ...ow When you push only one side at the temporary insert condition maximum slanted degree have to be less than 5 Deformation of the connector doesn t occur if insertion angle is kept less than 5 degree...

Page 8: ...ed un mating might cause deformations of FPC or damage on FPC pattern OK horizontal un mating OK condition 11 Fig 11 NG Slanted un mating NG 5 To use this connector safely please withdraw plug up to a...

Page 9: ...described in Fig 11 Caution Except for part if you pull up the LOCK BAR towards direction LOCK BAR would have deformation or the connector would have damage Also if you use Insulated part of LOCK BAR...

Page 10: ...13 As Fig 14 please make un mating by pulling the horizontal part in parallel to PCB Caution Except for part if you pull up the LOCK BAR towards direction LOCK BAR would have deformation or the connec...

Page 11: ...C is pulled to the vertical direction or slanted direction SHELL of the receptacle connector can deform or FPC might pull out from plug Please don t pull FPC vertically or with slanted angle LOCK BAR...

Page 12: ...too much pulling force to FPC Please refrain from applying pulling force or repeated bending force to the FPC assembly part of a plug connector 15 Fig 15 16 FPC Please refrain from applying cable ret...

Reviews: