background image

 

EVAFLEX 5-SE-GHT Connector Instruction Manual

 

Document No. 

HIM-18018

 

 

 
 

 

6

  / 

9

 

Confidential C                                                                   

FFC/FPC

抜去手順/

FFC/FPC Withdrawal Method

 

①  図

3-1

の様に、

FFC

をつまみながらロック解除ボタンを押す。

 

     

 

Push a release button on the connector while pinching the FFC/FPC. 

 

 

 

 

 

 

 

 

 

 

 

 

②  図

3-2

の様に、確実にロック解除ボタンを押したまま

FFC/FPC

を嵌合間口に対し垂直に引き抜く。

 

Withdraw FFC/FPC from the connector vertically while pushing the release button. (Fig.3-2)   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFC

と解除ボタンをつまむ

 

/ Pinch release button and FFC/FPC 

. 3-1 FFC/FPC

抜去方法

  1 / Fig.3-1 Pushing Release Button 

解除ボタンを押し込む

 

/ Push release button 

Push 

. 3-2 FFC/FPC

抜去方法

  2/ Fig.3-2 Withdrawing FFC/FPC 

FFC/FPC

は嵌合間口に対し垂直に引き抜いて下さい。

 

回転抜去

(

.3-3)

を行うと、

FFC/FPC

のパターンにダメージを与える恐れがありますので、

 

極力行わないで下さい。回転抜去を行ってしまった場合は、

 

FFC/FPC

のパターンのダメージを確認の上、御使用願います。

(

写真

  3-1 ) 

Withdraw FFC/FPC from connector vertically. 

Do  not  withdraw  FFC/FPC  with  rotation  (Fig.3-3)  or  it  may  damage  FFC/FPC  pattern.  If  fail  to  do  so,  make  sure  that 

FFC/FPC pattern is not damage before its usage. (Photo.3-1) 

Check! 

解除ボタンは自動で戻る

 

/ Releasing button returns to 
  its original position automatically. 

Summary of Contents for EVAFLEX 5-SE-GHT

Page 1: ...o HIM 18018 Confidential C I PEX Inc QKE DFFDE09 03 REV 8 EVAFLEX 5 SE GHT Part No 20899 0 E 01 Instruction Manual 0 S19209 March 26 2019 M Nakamura T Kurachi H Ikari Rev ECN Date Prepared by Checked...

Page 2: ...le EVAFLEX 5 SE GHT connector properly and safely connector Product Name EVAFLEX 5 SE GHT Part No 20899 0 E 01 Note1 Note 1 Connector position number Labelled Diagram of the Connector Mating throttle...

Page 3: ...so that the pattern faces PCB side as shown in Figure 2 1 insert it parallel to the PCB 2 1 FFC FPC 1 Fig 2 1 FFC FPC Pattern Facing Correct Direction 2 2 FFC FPC NG 1 Fig 2 2 FFC FPC Pattern Facing W...

Page 4: ...wable angle is maximum 10 degrees Fig 2 4 a Slightly insert the connector Connector pitch direction without applying excessive load Insert FFC FPC fully until it is vertical to the connector 2 4 b 15...

Page 5: ...ck or may deform connector or FFC FPC 2 Caution 2 2 6 15 FFC FPC Do not exceed 15 degrees angle or it will not be locked nor may deform connector or FFC FPC 2 5 FFC FPC NG 2 Fig 2 5 Bad FFC FPC insert...

Page 6: ...e button Fig 3 2 FFC Pinch release button and FFC FPC 3 1 FFC FPC 1 Fig 3 1 Pushing Release Button Push release button Push 3 2 FFC FPC 2 Fig 3 2 Withdrawing FFC FPC FFC FPC 3 3 FFC FPC FFC FPC 3 1 Wi...

Page 7: ...rt circuit 4 Caution 4 Do not push the release button using the nails it may deform nor cause short circuit 3 4 FFC FPC NG 2 Fig 3 4 Bad Ways to Push Release Button 3 5 FFC FPC NG 3 Fig 3 5 Bad Ways t...

Page 8: ...dly withdraw FFC FPC without pushing a release button as this may damage FFC FPC or the connector 3 6 FFC FPC NG 4 Fig 3 6 Withdrawing FFC FPC Without Pushing Release Button Damage b Properly Withdraw...

Page 9: ...his may damage FFC FPC or the connector See Photo 4 1 FFC FPC FFC FPC FFC FPC Do not apply excessive force to the connector and FFC FPC or they may be damaged FFC FPC FFC FPC Do not pull around FFC FP...

Reviews: