background image

 

FPL II CONN. Instruction Manual

 

Document No. 

HIM-09007 

 

 
 

 

2

  / 

7

 

Confidential C                                                                                                                                                                                                   

1. 

目的

  (Purpose) 

   

FPL

Ⅱコネクタの取り扱いに際して、本コネクタを安全に御使用頂くことを目的とし

 

コネクタの挿入、抜去の注意点を記述いたします。

 

This user manual is applied for FPL

series connectors in order to instruct how to use the connectors safely. 

The manual contains notice points for mating and un-mating process. 

 

2. 

対象コネクタ

  (Objective connector) 

 

       

FPL

Ⅱ 

CONN.

 

PLUG

 

CABLE

 

ASS’Y

 

(Harness Side) 

                   

P/N

・・・・

20437-0**T-*1 

 

    FPL

Ⅱ 

CONN.

 

RECE (PCB. Side) 

                          P/N

・・・・

20439-0**E-** 

 

    3.

挿入手順

  (Mating process) : 

 

     

① 

ハーネス側(

PLUG

)コネクタと基板側(

RECE

)コネクタの嵌合方向は、図

1

の様に

 

ケーブルと

RECE

 

CONTACT

の半田付け部が反対方向となるようになります。

 

真上から

RECECONTACT

の半田付け部がケーブルで隠れていなか確認してください。

 

ハーネス側(

PLUG

)コネクタが逆向きですと、挿入出来ません。

 

Please set harness side (Plug) and receptacle connector contact (RECE) as the same as fig 1. 

The direction of cable side of the harness is opposite with contact soldering side of the receptacle. 

Please confirm whether the soldering tail is hidden by the cable or not from top view.   

If the direction is opposite, mating process isn’t able to be finished . 

   

       

               

 

1

Fig. 1

):嵌合方向

/Mating direction

 

 

 

ケーブル

(Cable side) 

  半田付け部

(Soldering side) 

Summary of Contents for FPL II

Page 1: ...al C I PEX Inc QKE DFFDE09 03 REV 8 FPL II CONN Part No 20437 0 T 1 Instruction Manual 2 S15417 September 10 2015 H I E K 1 S13299 July 19 2013 H A E K 0 S12055 February 7 2012 H A J T T H Rev ECN Dat...

Page 2: ...s Side P N 20437 0 T 1 FPL CONN RECE PCB Side P N 20439 0 E 3 Mating process PLUG RECE 1 RECE CONTACT RECECONTACT PLUG Please set harness side Plug and receptacle connector contact RECE as the same as...

Page 3: ...e cable side connector from above At that time you can feel the click feeling Then press both connector ends to confirm it is not one side mating 2 Fig 2 OK Mating Method OK 3 Fig 3 Push position 1 Ph...

Page 4: ...or half mating condition 3 Photo 3 OK 4 Fig 4 OK Mating Condition OK Mating Condition OK 4 Photo 4 NG Mating Condition NG 5 Photo 5 NG 6 Photo 6 NG Mating Condition NG Mating Condition NG NG NG NG 0 1...

Page 5: ...onfidential C 5 6 If the plug is inserted into RECE just by one side the other side may rotate when mating with RECE Fig 5 6 It will damage the connectors and we hope to avoid mating like that 5 Fig 5...

Page 6: ...talled in the shell to un mate from RECE vertically Fig 7 7 Fig 7 1 OK Un mating Method 1 OK 7 If you find the pulling tape is not vertical over top shell as Photo 7 showed there is no any problem to...

Page 7: ...ruction Manual Document No HIM 09007 7 7 Confidential C 8 Fig 8 NG Un mating method NG NG 8 9 If you un mate the plug by rotating the plug as Fig 8 9 the connector may be damaged 9 Fig 9 NG Un mating...

Reviews: