ISH HYBRID CONNECTOR Instruction Manual
Document No.
HDM-0009
16
/
24
Confidential C
7.How to release female terminals
(
※
Use the exclusive jig, or a jig of which tip shape dimension is corresponded to Fig33.)
①
Ensure that the rear holder and the retainer have been removed.
②
Hold the wire and push in the female terminal lightly. Place the female terminal releasing jig into
the releasing apertures of the female housing (see Figs. 31 and 32).
③
Push the releasing jig fully into the lance, then lever up the lance as shown in Fig.34 and 35 .
Keep the jig in the place and pull the terminal out by holding the wire.
④
If there is any difficulty in pulling out the terminal, do not pull it forcefully. Check that the jig is in the correct place, that it is pushed fully in, etc.
and repeat the procedures
①
to
③
.
Place flat surface of the jig outside.
Terminal releasing jig
Fig31.Housing and Direction of release
Fig 32. Releasing apertures location
0.5mm Female terminal
:
VT001-512
Terminal releasing jig
:
AP0004-01-005
1.5mm Female terminal
:
VT004-513
Terminal releasing jig
:
AP0037-01-001
1.5mm Female Terminal
releasing jig aperture
0.5mm Female Terminal
releasing jig aperture