ISH HYBRID CONNECTOR Instruction Manual
Document No.
HDM-0009
4
/
24
Confidential C
3. Crimping procedure
3-1.Applicable wires
3-2. Wire strip length
①
Strip the insulation off at the dimension shown in Fig .1.
②
Check to see that there is no damage to the conductors or insulation, cut off conductors, short conductors
and deformed conductors as shown in Fig. 2.
Do not use wires with damaged conductors, cut off conductors, short conductor and deformed conductors.
Using faulty wires may cause crimping problems.
VT004-513
1.5mm
Part No
Terminal
Tab Size
Applicable Wire
VT001-512
0.5mm
Wire Size
:
0.3mm
2
・
0.5mm
2
Insulation Outer Diameter
:
φ1.60mm MAX.
Wire Size
:
0.5mm
2
Insulation Outer Diameter
:
φ1.93mm MAX.
Part No
Dimension [A]
VT001-512
3.0±0.1mm
VT004-513
4.0±0.1mm
Terminal
Tab Size
0.5mm
1.5mm
[ ]
Conductors
Insulation
Deformed conductors
(defect)
Damaged conductors
(defect)
Cut off conductors
(defect)
Condition
Image
Good
Fig 1.Wire strip
Table1.Applicable Wire
Fig 2. Stripped wires (unacceptable examples)