3-3. Terminal part names
3-4. Crimping requirements
(1)Crimp dimension
Female Terminals must satisfy the crimp dimension specified in Table 2.
※
Crimp dimensions may be different depending on conductor construction of the wire.
Please contact our Sales Department shown in 15(sheet 24) about wire used, then we will verify it and
notify you the appropriate crimp dimensions.
VT004-513
0.5mm
2
Φ1.93mm MAX.
1.00±0.05mm
1.60±0.05mm
2.00 mm
0.5mm
1.5mm
Terminal
Tab Size
Part No.
Wire Size
Insulation Outer Diameter
Wire barrel
Crimp Height(
※
)
Wire barrel
Crimp width
Insulation barrel
Crimp height
Insulation barrel
Crimp width
VT001-512
Φ1.60mm MAX.
1.40±0.04mm
1.55±0.05mm
1.60 mm
1.80±0.05mm
2.00±0.05mm
0.3mm
2
0.90±0.05mm
0.95±0.05mm
0.5mm
2
+0.10
- 0.05
+0.10
- 0.05
Fig 3. Terminal part names