(2)  FPC/FFC を未挿入状態でのアクチュエータのロック操作は避けてください。 

接点間が狭くなり、FPC/FFC 挿入力が上昇する恐れがあります。 
Please avoid actuator lock operation at the time of FPC/FFC un-inserting. 
Contact point gap becomes narrow and it becomes the cause by which FPC/FFC insertion   
power goes up. 

 

(3)  アクチュエータ操作の際に、過大な力を加えないで下さい。 

コネクタ破損の原因となります。 
Please do not apply excessive force, when you operate an actuator. 
It becomes the cause of connector breakage. 
 

(4)  アクチュエータのロック操作の際は、アクチュエータを FPC/FFC 挿入方向から Fig.3 の矢印方向に、指の腹で押してください。 

In the case of lock operation of Actuator, Please push an actuator in the direction of an arrow of   
Fig.3 in the inside of a finger from FPC/FFC insertion. 

 

 

Fig.3.  アクチュエータのロック操作方法  (The lock operation method of Actuator) 

 
(5)  アクチュエータのロック解除操作の際は、アクチュエータの溝部を Fig.4 の矢印方向に引き上げてください。 

基板に対して水平方向に力を加えながらのロック解除操作は、アクチュエータの破損の原因となります(Fig.5 参照)。 
In the case of release operation of Actuator, please pull up the slot on the actuator in the direction   
of an arrow of Fig.4. 
If lock release operation is performed imposing power horizontally to a PCB, it will become the   
cause of breakage of an actuator. (Refer to Fig.5.) 

 

 

Summary of Contents for MINIFLEX 5-BF II

Page 1: ...TACT GAP TYPE 20477 0 E type i STANDARD TYPE 20478 0 E type i WIDE CONTACT GAP TYPE MINIFLEX 5 BF III 20593 0 E 01 Instruction Manual 5 S19612 October 1 2019 R Morita T Masunaga H Ikari 4 S17804 Novem...

Page 2: ...OTICE 1 1 Notes at the time of operation Fig 1 Actuator un lock state Fig 2 Actuator lock state 1 FPC FFC Please insert FPC FFC completely and straightly to a connector It becomes the cause that spoil...

Page 3: ...ctuator It becomes the cause of connector breakage 4 FPC FFC Fig 3 In the case of lock operation of Actuator Please push an actuator in the direction of an arrow of Fig 3 in the inside of a finger fro...

Page 4: ...od 6 FPC FFC FPC FFC Please do not perform insertion and drawing out of FPC FFC in the state where the actuator was locked It becomes the causes contact instability by FPC FFC breakage and contact def...

Page 5: ...1 FPC FFC Please perform leading about of FPC FFC so that direct power is not applied to a connector Use in the state where power is applied to a connector becomes the cause contact instability 2 FPC...

Page 6: ...2 FPC FPC FPC Please do not locking the actuator when soldering connector There is the possibility that contact buckling FPC damage and FPC insertion force rises in inserting FPC because the gap of c...

Page 7: ...not force soldering iron on a Contact and Hold Down It becomes the cause of Contact and Hold Down deformation Please do not apply soldering iron other than Contact and Hold Down part It becomes the c...

Reviews: