IMPORTANT
•
No setting contents are determined unless the [Set] button is clicked.
•
To check the image after configuring VIQS, display an H.265 (or H.264) image on the “Live” page, or
press the [Confirm] button under “Stream”.
•
The outputted bit rate changes depending on the subject. Confirm the bit rates with actual subjects
used when operating the camera.
•
If the larger range is specified, the output bit rate increases. Check the current output bit rate to decide
the area size.
3.6.4.7 Register the initial installation angle of view
By registering the initial installation angle of view, you can be notified by an indicator, email notification, or
original alarm notification when the angle of view deviates.
For the indicator, refer to the included installation procedure leaflet.
For email notification, refer to “3.10.2.1 Configure the settings related to sending E-mails”.
For original alarm notification, refer to “3.8.2.4 Configure settings relating to TCP alarm notification when an
alarm occurs”.
[Registering the installation angle of view]
Click [Display] to display an image showing the amount of deviation from the position when registering the
installation angle of view, the pitch direction of the camera, and the roll direction. For information about the
displayed content, refer to
S
in “1.1.2 About the “Live” page”.
[Angle of view registration]
Click [Execute] to save the current position as the “initial installation angle of view”. Click [Delete] to delete the
“initial installation angle of view”.
[Angle of view error lamp]
Set “On” or “Off” whether to notify by using the LED indicator if the deviation from the initial installation angle
of view occurs.
•
Default:
On
Note
•
If the initial installation angle of view is not configured, the angle of view error lamp will not operate.
•
If the amount of deviation is small, the angle of view error indicator will not operate.
•
If the indicator display is blinking, the red LED indicator and green LED indicator blink when the angle
of view of the camera deviates.
•
If you register the initial installation angle of view and select [Diag.] in the [Advanced] tab -
“SMTP(E-mail)” - [Address 1] to [Address 4], you will be notified by e-mail when the angle of view
deviates and when it is corrected.
If you also select “Diag.” in the [Notification] tab - [TCP alarm notification], you will be notified by the
original alarm when the angle of view deviates and when it is corrected.
102
Operating Instructions
3 Detailed Settings