6 - FUNCTIONING
6-1
6 - 6
Mill
11. 1=YES
If set at 1 the mill is present
0
(mill not present)
# test mill
12. #
This is the number of times the mill is
checked for absorption during the
time set in parameter 12. If
absorption exceeds the limit for n.
times, the controller signals the
alarm.
3
t. test mill
13. x 100 ms
This is the length of time for
parameter 11
300
(= 30 seconds)
t. pause bin
14. sec
Bin pause time when an inversion of
direction is commanded.
15
t. start aspirator
15. sec
The length of time at start up, when
only the aspirator is in function to
remove any residual material.
5
t. start mill
16. sec
The length of time at start up, when
the mill is actuated, following the
parameter 15 length of time, to allow
removal of any residual material.
5
Time sensors
17. ms
The time expressed in milliseconds,
within which the current sensors must
signal continuous overload, before
any blocking actions are carried out,
so as to avoid brief overloads causing
false inversions.
15
T. belt if error
18. sec
This is the time in seconds within
which the belt is stopped if the mill or
shredder are meeting resistance.
10
Start key
19 2=EXT
Indicates whether to use the stop
drive push-buttons present on the
operator control panel (PARAMETER
= 1), or to use those external to the
operator control panel, but with input
on PLC (PARAMETER = 0), or
start/stop external circuit with auxiliary
sectioning (PARAMETER = 2), in
which case the PLC checks only the
“
drive
”
input.
1 = INTERNAL
(actuated by user
panel)
Summary of Contents for Tritotutto 50
Page 14: ...2 DESCRIPTION OF THE MACHINE AND TECHNICAL CHARACTERISTICS 2 1 I 2 3 2 3 OVERALL SIZE ...
Page 54: ...10 LIST OF SPARE PARTS 10 1 I 10 1 INDEX 10 1 RULES FOR ORDERING SPARE PARTS 2 ...
Page 56: ...11 DOCUMENTS ENCLOSED 11 1 I 11 1 INDEX 11 1 LIST OF ENCLOSURES 2 ...
Page 57: ...I 11 DOCUMENTAZIONE ALLEGATA 11 1 11 2 11 1 LIST OF ENCLOSURES ELECTRICAL DIAGRAMS ...