EN
7
SCOPE OF DELIVERY
Your device packaging contains the following:
1 x
IS-TC1A.M1
1 x Operating Manual Safety Instructions
1 x Screwdriver
INSTALLATION
DANGER
Improper use can result in death or severe injuries! Only connect the device outside explosion
hazardous areas to the ISM interface of the
IS530.M1
.
2
3
5
4
1
Unscrew the cover of the ISM interface (1) located on the
IS530.M1
.
Push the
IS530.M1
completely into the holder (2) of the device.
Attach the plug on top of the ISM interface (3).
Fix the plug by pressing the rounded end of the plug (4).
Tighten the screw (5).
Check whether the plug is correctly and firmly attached to the ISM interface.
The device can now be used together with the
IS530.M1
in explosion hazardous areas.
INITIATION
NOTE:
The following information applies to
IS-TC1A.M1
in combination with the
IS530.M1
.
Download and install the
Seek Thermal
application from the Google Playstore.
Open the
Seek Thermal
application at the
IS530.M1
and you can start immediately
.