30
6.3.2
Removing the spray nozzle
You can remove the spray nozzle by following the procedure shown in section 6.1.3 in reversed
order.
6.4
Cleaning and storage
WARNING
•
DO NOT
clean the i-cover® 2.5 with a high pressure cleaner;
•
DO NOT
submerge the i-cover 2.5 in water;
•
turn off the i-cover 2.5 and remove the batteries.
6.4.1
Cleaning the body of the i-cover 2.5
Wipe the body of the i-cover 2.5 after each use.
6.4.2
Flushing the spray nozzle
To prevent blockage of the spray nozzle, it is recommended to flush the spray nozzle with tap water
after each use. Or use an ultrasonic cleaner.
1.
Remove the spray nozzle, see section 6.3.2.
2.
Flush the spray nozzle (Figure 21, pos 1) with
tap water.
3.
Place the spray nozzle back in the spray gun
or extension tube, see section 6.1.3.
4.
Wipe the spray gun with a damp cloth.
Figure 21