background image

i

OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)

MECHANICAL  INSTALLATION

The label on the controller identifies the serial number, wiring connections and batch number.

CAUTION: To prevent the risk of electrical shock, switch off the power before making/removing any connection or 

removing the controller from  its enclosure.

INSTALLATION GUIDELINES

1.  Prepare  the  cut-out  with  proper  dimension  as  shown  in 

figure.      

2.  Remove clamp from controller 
3.  Push  the  controller  through  panel  cut-out  and  secure  the 

controller in its place by tightening the side clamp.

A

B

D

E

G

F

MODEL:-AI-7441/7741/7941  

PANEL

CUTOUT

C

H

C

H

MODEL : AI -7841

B

A

E

D

G

F

PANEL

CUTOUT

2

OIM AI-7X41 V2.1 Page 2 of 5

TABLE : 1

Model

Dim

48 

72

96

48

48 

72

96

96

8    

10

10   

10

75 

65

45

45

44

68

92

92

44

68

92

44

9

9

9

9

A

B

H

C

D

F

G

E

43

66

89

43

AI-7441

AI-7741

AI-7941

AI-7841

ELECTRICAL INSTALLATION

The electrical connection diagram is shown on the controller enclosure as below.

AI - 7441

AI - 7941

1

2

3

4

5

6

7

8

9

10

11 12 13 14 15 16 17 18

NO

NC

CM

RELAY

SSR

SUPPLY

L

N

1

2

3

4

5

6

7

8

9

10

11 12 13 14 15 16 17 18

NO

NC

CM

RELAY

SSR

SUPPLY

L

N

AI - 7841

AI - 7741

SUPPL

Y

L

N

1

2

3

4

5

6

7

8

9

10

11 12

15

16

13

14

NO

NC

CM

RELAY

SSR

SUPPLY

L

N

1

2

3

4

5

6

7

8

9

10

11

13

14

15

16

12

NO

NC

CM

SSR

RELAY

Glows when OP1 is ON & flashes when delay time (dly1) is in operation(if selected mode is ON-OFF)

It will display (1)Measured value of selected input or Error massages. (2) SP value in run mode. 
Parameters Values/code in program mode

1

2

OP1 LED

UPPER

DISPLAY

Sr. 

NAME

FUNCTION

(

(

(

along with UP key. (4) To scroll the parameter & to store its value.

1) For SP programming.  2) To access Control mode.  3) To access Configuration mode 

(

(

(with SET key) . (3) To acknowledge Alarm. (4) To enter in tune mode (with DOWN Key).

1) To increase/alter parameter value in program mode.  2) To Enter in configuration mode 

(

(

To enter in tune mode (with    

UP Key). 

1) To decrease / alter parameter value in program mode.  2) 

4

5

6

7

SET

KEY

SHIFT

KEY

UP

KEY

DOWN

KEY

(1) To increase/alter parameter value in program mode with Up / Dn Key.
(2) Press for 3Sec in Programming this will help to go back to previous parameter.

FRONT PANEL LAYOUT DESCRIPTION :

AI - 7441

AI - 7741

AI - 7941

FRONT PANEL LAYOUT

3

4

5

6

1

2

AI-7441

OP1

°C

SET

AT

5

6

3

4

1

2

OP1

°C

-therm

i

AI-7741

SET

AT

1

3

4

5

6

2

OP1

°C

SET

AT

-therm

i

AI-7941

AI - 7841

OP1

SET

AT

-therm

i

AI-7841

°C

1

2

3

5

4

6

Reviews: