MAJ : 16.09.11
8
Installation of floor-mounting temperature sensor
The floor temperature sensor is installed when you perform your heating element (mat or cable
section) installation. The Sensor is connected to the thermostat via a junction box. Place the sensor
in the corrugated plastic tube near its end, and seal this end of the tube to prevent penetration of
water, tile fixing mixture or cement mortar during the installation of the heating system. The tube
containing the temperature sensor must be located at the same level as the heating cable between
two neighbouring passes of this cable. Place the tube in a prepared groove in the floor and lead its
other end to the place chosen for the thermostat or junction box location.
Thermostat installation
Preparation of electrical connections
Install the plastic junction box into the wall where the location of the thermostat is planned. Lead the power supply cable, the
cold leads of the heating mat or section, and the temperature sensor cable, into the box.
First of all disassemble the thermostat. Take off the front cover, using a thin screwdriver, carefully
press in the locks located on the upper and lower sides of the front cover pulling it out slightly
Remove the cover. Remove the frame.
Assemble the thermostat acting in reverse order. Install the frame carefully ensuring that it
closely fits to the device's case. Then return the front cover to its place and press it ensuring that
both locks are fixed.