Technical data 

   

Supply voltage

   

240 V AC , 50/60 Hz

   

Maximum load current

   

16A   

Consuming power

   

0,45W

   

Weight

   

150 g

   

Dimensions

   

80 

×

 80 

×

 52 mm

   

Time of setting storage when supply is disconnected

   

12 Month

   

Ingress Protection

   

IP20

   

Floor mounting temperature sensor

   

NTC 6,8 k?

   

Length of sensor connection cable

   

2 m

   

Allowable ambient air temperature

   

+5 up to +45 °C

   

Allowable relative air humidity

   

80%

   

Maintaining temperature range

   

+5 up to +35 °N

   

Factory preset

   

+25 °N

   

   

ACCEPTANCE TEST CERTIFICATE

 

The thermostat I-Warm 760 passed the test. 
Name:   

 

Street: 

 

ZIP code, city: 

 

Country: 

 

Phone: 

E-Mail: 

Date of purchase:   

Installer:     

Installation date:     

Signature installer:   

   

If you have questions, please contact :  

 

INNOV’HEAT 
BP 20 183 
59 444 WASQUEHAL 
FRANCE 
Tel : + 33 (0) 982 38 33 44 
Mail : contact@innovheat.com 

   

Summary of Contents for 760

Page 1: ...l skill of the device installer We recommand that you apply for professional service for the thermostat and heating system installation Only qualified electricians should perform the connections and power networking of the device Switch off power before connecting wiring to the thermostat or disconnecting the device for testing Start up Don t turn the newly built heating system on before the tile ...

Page 2: ...display Start up of the thermostat The thermostat can be turned on after wiring connections are complete and tested To turn the I WARM 760 ON OFF press the middle button for not less than 3 seconds Turning ON OFF is accompanied by an appropriate animation on the display After the I WARM 760 is turned on the basic indication appears on the highlighted display The larger numbers 20 C indicate the ac...

Page 3: ...rm the settings until the device will return to the main Menu To return to the basic indication choose the submenu Save settings and exit and press the Menu button Set the date and the time Entering the correct date and time ensures the correct operation in the daily and the weekly program modes To set the date and time press the Menu button while in the basic mode and choose the Set date and time...

Page 4: ...change them Setting the daily program To set the daily mode press the menu button to access the daily program while the thermostat operates in the main mode Browse by using the selection buttons to the subdivision program setting then press the menu button Then select the Program day item and press the menu button The submenu Program day appears Activate is for starting the daily mode with prior s...

Page 5: ...s while the thermostat operates in the main mode Activate the subdivision program settings with the menu button Then select the Program week item and press the menu button The submenu Program week appears Activate is for starting the weekly mode with prior set parameters The view item allows you to view the heating diagram without being able to edit it The edit item enables you to set a heating sc...

Page 6: ...r heating program within one minute the device will return to operate in the previously chosen mode the data you entered will not be saved Control of the heating system operating conditions The I WARM 760 thermostat permanently controls the operating condition of the heating system If the heating of the floor surface to the preset temperature appears to be impossible the ATTENTION sign is displaye...

Page 7: ...Save settings and exit and press the menu button The I WARM 760 will return to its current operation and indication mode Warranty During the warranty period the customer has the right to get the product repaired or replaced due to faulty materials from the manufacturer on the condition that the manual guides to Installation and Operation of this device have been followed The warranty policy does n...

Page 8: ...e in the floor and lead its other end to the place chosen for the thermostat or junction box location Thermostat installation Preparation of electrical connections Install the plastic junction box into the wall where the location of the thermostat is planned Lead the power supply cable the cold leads of the heating mat or section and the temperature sensor cable into the box First of all disassemb...

Page 9: ... sensor connection cable 2 m Allowable ambient air temperature 5 up to 45 C Allowable relative air humidity 80 Maintaining temperature range 5 up to 35 N Factory preset 25 N ACCEPTANCE TEST CERTIFICATE The thermostat I Warm 760 passed the test Name Street ZIP code city Country Phone E Mail Date of purchase Installer Installation date Signature installer If you have questions please contact INNOV H...