10
Installation
guide
INSTALLATION GUIDE
2
Installation of the floor temperature
sensor
Mounting the floor temperature sensor is carried out at the stage of the
heating element installation. The floor temperature sensor should
be placed inside the corrugated tube (see fig. 3), the end of the tube
should be closed with sealing blank cover to prevent concrete mixture
or tile adhesive glue penetration at the warm floor system
installation. The corrugated tube with the sensor inside should be
placed at the same level as the heating cable, between the loops at
equal distances from them. The other end of the corrugated tube with
the sensor installation wire inside should be laid in the prepared groove
(chase) in the floor and lead to the installation place of the
thermostat or the junction box. Excess of the tube and connection
wire should be cut as applicable.
De-energize the wiring system before you connect the
thermostat or disconnect it to check or replace.
A qualified electrician is to perform the electrical connections
and power networking.
The warranty does not cover any thermostat defects caused
by inadequate installation.
IMPORTANT Please read this manual carefully before you start
operation.
Summary of Contents for MCS 300
Page 1: ...Mobile Comfort System Technical Certificate User Manual Thermostat MCS 300 ...
Page 9: ...Introduction 9 Fig 2 Thermostat MCS 300 with opened front cover 8 Controls and indication ...
Page 16: ...14 Installation guide Fig 7 Thermostat without cover ...
Page 21: ...Your safety 17 ...
Page 23: ...18 Warranty obligations ...
Page 25: ...Jihua Road East Buji Shenzhen China 518112 Warranty certificate 19 ...
Page 26: ......