Annexxus 516 Encoder - User Manual
5 LAN
10M/100/1000Mbps adaptive Ethernet interface
6 RESET
Restore Annexxus 516 unit to factory default settings by pressing the
RESET pin hole button for 15 seconds after the power is turned OFF
7 RS-485
RS-485 serial interface is provided for Pan/Tilt/Zoom support for PTZ
cameras.
8 ALARM IN
Relay alarm input (up to 16 sensors)
9 ALARM OUT Relay alarm output (up to 4 controls)
10 DC12V
12V DC power supply
11 GND
Grounding
Installation Instructions
1.
Connect up to 16 analog cameras to the BNC VIDEO IN ports on the back of the Annexxus 516 unit
2.
Connect the microphone or other two-way audio device to the LINE IN 3.5mm port, if using
3.
Connect the speakers, or other audio output device to the AUDIO OUT 3.5mm port, if using
4.
Connect up to 16 audio inputs to the AUDIO IN ports, if using. Audio Port number corresponds and is hard-linked
with the Video Port number. Make sure to connect audio inputs to the corresponding video channels.
5.
Connect a network cable to the LAN port on the back of the Annexxus 516 unit, plug in the other end of the
cable to SRX-Pro Server for a direct/cross-over connection or plug into the Gigabit switch if using on the network
or connecting multiple Annexxus 516 units.
6.
Connect PTZ control cables from PTZ cameras to RS-485 port on the back of the Annexxus 516 unit, if using.
7.
Connect up to 16 sensor inputs to ALARM IN ports, if using.
8.
Connect up to 4 control relay outputs to ALARM OUT ports, if using.
9.
Connect the 12VDC power adapter to your Annexxus 516 unit.
10.
Connect the power cable to the 12VDC power adapter.
11.
Lastly, plug in the power cable into the power source. The use of UPS (Uninterrupted Power Supply) is highly
recommended to extend the life of your unit. Annexxus 516 unit will power on automatically.