background image

i3-TRNG-DVR-

U3i_U30_QSG

.indd

Rev. 220419

Note: Unmarked components are not in use.

No. Item

Description

1

Keys

Front panel keys. 

Tip: 

Lock the front panel to restrict 

access to storage hard drives.

2

USB 3.1

4x USB 3.1 interfaces

3

VGA

1x VGA video output

4

DP++

2x Dual-Mode Disp+ ports (4K monitors 

supported)

5

Network Port

2x RJ45 10/100/1000 Mbps Ethernet interface

IP CAM (left) - connect to the IP Camera network

WAN (right) - connect to the Internet (WAN) network

6

Power Switch

Power ON/OFF

7

AC Power In

AC Power in Port

U3i/U30

SRX-Pro 64-channel NVR

Quick Start Guide

6 7

2 3 4

5

4

2

1

Thank you for purchasing i3 International’s 64-channel NVR. Your NVR comes 

pre-installed with i3’s flagship SRX-Pro software and i3Ai software (U3i only). 

Purchase enough IP licenses and i3Ai licenses (U3i only) for your desired solution.

SAFETY

When installing your NVR, be sure to:
• 

avoid excessive heat, such as direct 

sunlight or heating appliances

• 

avoid contaminants (e.g. dust, smoke)

• 

strong magnetic fields

• 

avoid moisture and humidity

• 

avoid areas with mechanical vibrations

• 

avoid temperatures below 10°C (50°F) 

and above 30°C (86°F).

• 

use VW-1 or FT-1 cables only

CAUTION:  Risk of Explosion if Battery is replaced by an Incorrect Type. 

Dispose of Used Batteries According to the Instructions.

ATTENTION: Risque d’explosion si la batterie est remplacée par un type 

incorrect. Mettre au rebus les batteries usagées selon les instructions.

Equipment is intended for installation in Restricted Access Area. 

Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS 

RESTREINT

The inside of the equipment is intended for service access only.

WARNING: Hazardous Moving Parts. Keep body parts out of the motion 

path.

AVERTISSEMENT: Parties mobiles dangereuses.  Se tenir à lécart de la 

zone de mouvement des parties mobiles

POWER SUPPLY

Power consumption requirements: 100~240VAC.

PACKAGE CONTENTS

Ensure that the items received match the following. In addition to this Quick Guide 

and the NVR, the packing box includes:

1. 

USB ke mouse (x1)

2. 

Power cable (x1)

3. 

HDMI to HDMI cable (x1) 

4. 

Security label (x1)

INSTALLATION

Your NVR can be Rack-mounted and requires 3.5U of rack space. Follow all safety 

precautions when selecting an installation location for your NVR. 

 

Reminder: 

Use i3 approved HDD models 

only

 (Western Digital Gold and Ultrastar).

Tip: 

Ensure the NVR is within 1 meter (3 feet) from the UPS and the NVR and its cables 

have sufficient space. The system must be placed on an even surface (shelf or Rack 

mount).

1. 

Turn the Power Switch (#6) to the OFF position.

2. 

Plug the USB mouse and the USB keyboard into the USB ports (#2).

3. 

Plug the VGA (#3), DP++ (#4), or HDMI (via cable provided) monitor.

4. 

Plug IP cameras into a Gigabit Switch and connect to IP CAM RJ45 port (#5).

5. 

Use the RJ45 Ethernet port labeled WAN (#5) to connect your NVR to network.

6. 

Plug in the supplied power cable into the AC Power In port (#7) and connect 

the NVR to an Uninterrupted Power Supply (UPS). 

Note: 

Uninterrupted Power Supply usage is mandatory for the reliability and 

longevity of your NVR. Failure to use UPS may void your factory warranty.

7. 

Return the Power Switch (#7) into the ON position. The NVR will then power on. 

If not, press the Power button located on the front panel of the NVR.

RACK MOUNT INSTRUCTIONS

1. 

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack environment may be greater than 

room ambient. Therefore, consideration should be given to installing the equipment 

in an environment compatible with the maximum ambient temperature (Tma) 

specified by the manufacturer.

2. 

Reduced Air Flow - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment is not 

compromised.

3. 

Mechanical Loading - Mounting of the equipment in the rack should be such that a 

hazardous condition is not achieved due to uneven mechanical loading.

4. 

Circuit Overloading - Consideration should be given to the connection of the 

equipment to the supply circuit and the effect that overloading of the circuits might 

have on overcurrent protection and supply wiring. Appropriate consideration of 

equipment nameplate ratings should be used when addressing this concern.

5. 

Reliable Earthing - Reliable earthing of rack-mounted equipment should be 

maintained. Particular attention should be given to supply connections other than 

direct connections to the branch circuit (e.g. 

use of power strips).

FIRST STARTUP

Your NVR is running Windows 10 IoT OS and comes 

pre-installed with the latest version of 

SRX-Pro software.

As part of the first startup, you will need to:

A. 

Set a new administrative password.

B. 

Ensure the Time Zone is configured correctly.

Set New Admin Password

When the NVR first boots up, you will see the 

Windows Lock Screen 

1. 

Unlock the NVR with default 

credentials.

Username:

 i3admin

Password: 

i3admin

2. 

Click 

PRO

 icon in the SRX-Pro 

monitor utility 

to open SRX-Pro Setup in a web 

browser.

3. 

Set the new administrative password for 
i3admin username and click 

 

Follow suggested password guidelines 

for a strong password. 

 

Keep your new password secure.