i3 INTERNATIONAL INC.
1.866.840.0004
www.i3international.com
U.S.A 4450 Witmer Industrial Estates Unit 4
Niagara Falls, NY 14305
Canada 780 Birchmount Road, Unit 16,
Scarborough, ON, M1K 5H4
i3-TRNG-DVR-
Veo16p
.indd
Rev
.
181106
HVR COMPONENTS
Thank you for purchasing i3’s Embedded HVR Veo16p. Your HVR supports a total of 16
video inputs: IP (select i3 Annexxus models only) or analog/HD-TVI analog.
The following items should be included with your HVR. If any of these items are
missing, please contact your dealer or call our Customer Care Department toll free at
1.866.840.0004.
ACCESSORIES
1.
Power Cable (x1).
2.
12V DC Power Adapter (x1)
3.
Power cable retainer clip (x1)
4.
Hard Drive screws (x12)
5.
USB Mouse (x1)
6.
Remote Control and 2x AAA batteries
7.
7P Terminal block (x2). (Pre-installed).
8.
10P Terminal block (x4). (Pre-installed)
INSTALLATION REQUIREMENTS
When installing your Veo16p be sure to avoid:
•
Temperatures outside of the acceptable 20°C-25°C (68°F -77°F)
•
Humidity outside of acceptable range of 20%-80%, non-condensing
•
Contaminants such as dust and smoke
•
Areas with strong magnetic fields or mechanical vibrations
Important: an Uninterrupted Power Supply (UPS), minimum 1000 VA, with
a constant power of 118 to 120 AC must be used with each i3 HVR Server
to ensure longevity and to maintain warranty.
INSTALLATION
Before installation: Ground yourself. This will remove any static electrical charge your
body might be carrying.
STEP 1
Plug the
mouse
into the USB port in the front
15
or the back
8
of the unit.
STEP 2
Plug the main
monitor
into the VGA
5
or the HDMI port
6
on the motherboard.
To connect a DVI monitor, use HDMI-DVI adapter (not included).
Note: For proper display, your main monitor must support 1920 x1080 at 60Hz.
STEP 3
Connect Veo16p HVR to the
network
.
9
Connect a switch or a hub to the HVR’s WAN
port. Connect the switch with i3 IP cameras (Ax47/67, Ax45/65), if using, to the LAN port.
Note: Configure the IP cameras’ IP address before connecting to Veo16p.
STEP 4
Connect up to 16 analog
cameras
2
to the BNC ports on the back of the unit. If using
PTZ cameras, connect RS485 communication cable to the corresponding ports on the
back of the HVR. Connect up to 16 i3 IP
cameras
to the LAN NIC port. See CONNECTING
REMOTELY via INTERNET EXPLORER for more information.
The total number of cameras supported: 16, select i3 IP cameras, analog/HD-TVI analog
or a combination of the two.
STEP 5
Connect other peripheral devices, if using, such as RCA Audio Inputs/Output
1
3
,
Spot Out monitor(s)
4
, eSATA storage
7
, Alarm IN/OUT devices
10
, etc.
STEP 6
Connect the provided
12V DC Power Adapter
to the
power port
11
on the back of the HVR. Secure the power
cable with the power cable retainer clip (provided) then
fasten retainer clip to the opening
12
to help prevent
unintended disconnection of the power.
STEP 7
Connect the power cable to the
Uninterruptible Power Supply (UPS)
, 1000VA min., to
maintain warranty. Connect the UPS to the Power Source / power outlet.
STEP 8
The system will power on automatically. If this does not happen, press the power button
on the front of Veo16p HVR.
13
The system will then power up.
1
RCA Audio input ports (x16)
2
BNC Camera ports. Connect up to 16
analog cameras (max. 16 IP+analog).
3
RCA Audio Output (speaker) port
4
BNC Spot Out monitor ports (x2)
5
VGA monitor port
6
HDMI monitor port
7
eSATA port for external storage
8
USB port. Connect USB mouse or USB
storage.
9
WAN / LAN Ethernet ports.Connect a
switch or a hub to WAN port. Connect
the switch with up to 16 i3 IP cameras
(Ax45/Ax47/Ax67) to LAN port.
(max. 16 IP+analog)
10
Alarm In (x18), Alarm Out (x8), Relay
(x8), RS485 (x2) ports
11
12V DC Power Adapter port (provided)
12
Secure the power cable with the power
cable retainer clip, then fasten retainer
clip to the opening to help prevent
unintended disconnection of the power.
13
Power button. Press to turn the HVR on.
14
Channel selection buttons. Enter the
channel number to display individual
channels in the full screen mode.
1
2
3 4 5
6 7 8
9
10 11
12
18 19 20
17
15
14
16
13
21 22
23
24
25
26
27
28
29
30
15
USB ports x2. Connect USB mouse or
USB storage.
16
DISPLAY. Changes the camera split
screen: 1, 2x2, 3x3 or 4x4
17
ALARM. Displays alarm status in a
popup window.
18
MENU. Displays system menu.
19
ARCHIVE. Displays backup mode.
20
SEARCH. Displays Time Search mode.
21
PTZ. Displays PTZ Control mode.
22
CD/DVD eject button
23
FOCUS. Focus selected PTZ camera
Near/Far.
24
Pause. Freezes the playback video.
25
ZOOM IN/OUT. Zoom selected PTZ
camera In (tele) or Out (wide).
26
PANIC. Start the emergency recording.
27
Menu navigation buttons. Use the
arrows to move through the system
menus. Use the Enter button in the
middle to select a menu item or
confirm a setting.
28
RETURN. Return to the previous menu.
29
LOCK. Lock Veo16p to prevent all
operations.
30
ZOOM. Enter the digital zoom mode.
Then use Zoom In/Out buttons (#25)
HD Analog
Cameras x16
Mic
SPOT
Monitor
Speaker
VGA
Monitor
HDMI
Monitor
e-SATA
Storage
USB
Mouse
IP Router or
Gigabit Switch
Alarm IN /
Sensor x18
RS485
Control
Devices
RS232
Alarm
OUT x8
Switch with 16 i3 IP cameras
Quick Installation Guide
Veo16p Embedded HVR
BASIC LAYOUT
QR Code for Complete
User Manual